Skip to main content
Window · Vinyl Frame NFRC EWW · Product Line EWW-M-14 ENERGY STAR Most Efficient Eligible

EnergyWall Window — 7420/3120/8620 Double Hung · Double Hung

Positioning #136/1,352 in certified Window, EnergyWall Window 7420/3120/8620 Double Hung pairs Vinyl frame construction with 1,340 glazing options rated between 0.15 and 0.51 SHGC across Northern, North-Central, South-Central, Southern. Across 10 certified EnergyWall Window product families, its thermal resistance spans 0.15 to 0.32 U-Factor and the line includes 579 ENERGY STAR Most Efficient packages (43.2% of line).

Min U-Factor
0.15
SHGC Range
0.15-0.51
Certified Options
1,340
Category Standing
#136 of 1,352

How does EnergyWall Window 7420/3120/8620 Double Hung compare thermally against Window peers?

EnergyWall Window 7420/3120/8620 Double Hung achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 7420/3120/8620 Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 7420/3120/8620 Double Hung (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

7420/3120/8620 Double Hung Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 7420/3120/8620 Double Hung is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.15-0.32.

Mapping NFRC SHGC values (0.15 to 0.51) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 579 configurations meet ENERGY STAR Most Efficient criteria while 721 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2025-03-04. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.15 conducts 90.0 BTU/hr (-42.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,340 certified glazing combinations for 7420/3120/8620 Double Hung (NFRC EWW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 721 packages (295 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 977 packages (489 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 816 packages (400 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 835 packages (490 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does EnergyWall Window produce?

Compare other active EnergyWall Window certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to EnergyWall Window 7420/3120/8620 Double Hung appear below.

Where does EnergyWall Window 7420/3120/8620 Double Hung stand thermally among ENERGY STAR Window lines?

Testing puts EnergyWall Window 7420/3120/8620 Double Hung at rank #136 of 1,352 Window entries with U 0.15 to 0.32 across 1,340 configurations. Solar heat gain ranges between 0.15 and 0.51 across Northern, North-Central, South-Central, Southern.

Does EnergyWall Window 7420/3120/8620 Double Hung qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 721 7420/3120/8620 Double Hung packages (U floor 0.15, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from 7420/3120/8620 Double Hung's 0.15 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 7420/3120/8620 Double Hung at U 0.15 conducts 90.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip EnergyWall Window 7420/3120/8620 Double Hung and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 7420/3120/8620 Double Hung options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is 7420/3120/8620 Double Hung suitable for sunbelt cooling-dominated homes?

Exactly 835 7420/3120/8620 Double Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.15 rather than higher 0.51 glass.

What glazing share inside 7420/3120/8620 Double Hung qualifies as Most Efficient?

Within 7420/3120/8620 Double Hung, 43.2% (579 of 1,340) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

Do 2026 7420/3120/8620 Double Hung installations qualify for IRS Section 25C tax credits?

Any 7420/3120/8620 Double Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on 7420/3120/8620 Double Hung?

Inspectors match the temporary NFRC sticker (U 0.15-0.32, SHGC 0.15-0.51) against permit drawings for line EWW-M-14. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for EnergyWall Window 7420/3120/8620 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros