Skip to main content
Window · Vinyl Frame NFRC JEL · Product Line JEL-A-545 ENERGY STAR Most Efficient Eligible

JELD-WEN, inc. — Premium Vinyl (V-4500) SH/HS Fixed Direct Set · Picture Window

JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.15 across 2,473 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #136 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.60.

Min U-Factor
0.15
SHGC Range
0.14-0.60
Certified Options
2,473
Category Standing
#136 of 1,352

How does JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set compare thermally against Window peers?

JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Premium Vinyl (V-4500) SH/HS Fixed Direct SetHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Premium Vinyl (V-4500) SH/HS Fixed Direct Set (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Premium Vinyl (V-4500) SH/HS Fixed Direct Set Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set at rank #136 of 1,352 (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.14-0.60 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 117 configurations meet ENERGY STAR Most Efficient criteria while 463 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2026-10-30. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.15 conducts 90.0 BTU/hr (-42.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,473 certified glazing combinations for Premium Vinyl (V-4500) SH/HS Fixed Direct Set (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 463 packages (35 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,160 packages (34 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 900 packages (18 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,570 packages (93 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
EnergyWall Window — 8660 Awning Vinyl 0.15 0.14 2,542
Polaris Windows and Doors — 8660 Awning Vinyl 0.15 0.14 2,542
EnergyWall Window — 8650/3151 Casement Vinyl 0.15 0.14 2,568
Polaris Windows and Doors — 8650/3151 Casement Vinyl 0.15 0.14 2,568
Great Day Improvements, LLC — 8200 Picture Vinyl 0.15 0.17 1,974

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set appear below.

What U-Factor and SHGC range does JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set achieve?

Testing puts JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set at rank #136 of 1,352 Window entries with U 0.15 to 0.32 across 2,473 configurations. Solar heat gain ranges between 0.14 and 0.60 across Northern, North-Central, South-Central, Southern.

Is Premium Vinyl (V-4500) SH/HS Fixed Direct Set approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 463 Premium Vinyl (V-4500) SH/HS Fixed Direct Set packages (U floor 0.15, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

What conductive BTU/hr difference separates Premium Vinyl (V-4500) SH/HS Fixed Direct Set from the 0.22 Northern rule?

At U 0.15, a standard 3x5 ft (15 sq ft) Premium Vinyl (V-4500) SH/HS Fixed Direct Set opening transfers 90.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -42.0 BTU/hr difference.

Which situations make Premium Vinyl (V-4500) SH/HS Fixed Direct Set the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Premium Vinyl (V-4500) SH/HS Fixed Direct Set options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 1,570 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set, while total line SHGC reaches 0.60 in colder packages.

What glazing share inside Premium Vinyl (V-4500) SH/HS Fixed Direct Set qualifies as Most Efficient?

Not every package qualifies: 117 of 2,473 Premium Vinyl (V-4500) SH/HS Fixed Direct Set glazing builds earn Most Efficient recognition (4.7%), while other variants sit on the standard Version 7.0 tier.

What 2026 federal tax credit and Lead RRP rules apply to Premium Vinyl (V-4500) SH/HS Fixed Direct Set?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify Premium Vinyl (V-4500) SH/HS Fixed Direct Set glass specs on job sites?

Match the NFRC thermal sticker for code JEL and line JEL-A-545 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros