JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.15 across 2,473 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #136 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.60.
- Min U-Factor
- 0.15
- SHGC Range
- 0.14-0.60
- Certified Options
- 2,473
- Category Standing
- #136 of 1,352
How does JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set compare thermally against Window peers?
JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set at rank #136 of 1,352 (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.14-0.60 band.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 117 configurations meet ENERGY STAR Most Efficient criteria while 463 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2026-10-30. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.15 conducts 90.0 BTU/hr (-42.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 2,473 certified glazing combinations for Premium Vinyl (V-4500) SH/HS Fixed Direct Set (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 463 packages (35 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 1,160 packages (34 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 900 packages (18 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 1,570 packages (93 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| EnergyWall Window — 8660 Awning | Vinyl | 0.15 | 0.14 | 2,542 |
| Polaris Windows and Doors — 8660 Awning | Vinyl | 0.15 | 0.14 | 2,542 |
| EnergyWall Window — 8650/3151 Casement | Vinyl | 0.15 | 0.14 | 2,568 |
| Polaris Windows and Doors — 8650/3151 Casement | Vinyl | 0.15 | 0.14 | 2,568 |
| Great Day Improvements, LLC — 8200 Picture | Vinyl | 0.15 | 0.17 | 1,974 |
What other certified series does JELD-WEN, inc. produce?
Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
7500 Series Horizontal Slider
U-Factor 0.14–0.32 · 42,001 certified options.
Premium Vinyl (V-4500) Casement Fixed Direct Set
U-Factor 0.14–0.32 · 2,573 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set appear below.
What U-Factor and SHGC range does JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set achieve?
Testing puts JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set at rank #136 of 1,352 Window entries with U 0.15 to 0.32 across 2,473 configurations. Solar heat gain ranges between 0.14 and 0.60 across Northern, North-Central, South-Central, Southern.
Is Premium Vinyl (V-4500) SH/HS Fixed Direct Set approved for Northern Zone heating climates?
Prescriptive Northern compliance covers 463 Premium Vinyl (V-4500) SH/HS Fixed Direct Set packages (U floor 0.15, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.
What conductive BTU/hr difference separates Premium Vinyl (V-4500) SH/HS Fixed Direct Set from the 0.22 Northern rule?
At U 0.15, a standard 3x5 ft (15 sq ft) Premium Vinyl (V-4500) SH/HS Fixed Direct Set opening transfers 90.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -42.0 BTU/hr difference.
Which situations make Premium Vinyl (V-4500) SH/HS Fixed Direct Set the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Premium Vinyl (V-4500) SH/HS Fixed Direct Set options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Can you install JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set in Southern or South-Central zones?
Across Northern, North-Central, South-Central, Southern, 1,570 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set, while total line SHGC reaches 0.60 in colder packages.
What glazing share inside Premium Vinyl (V-4500) SH/HS Fixed Direct Set qualifies as Most Efficient?
Not every package qualifies: 117 of 2,473 Premium Vinyl (V-4500) SH/HS Fixed Direct Set glazing builds earn Most Efficient recognition (4.7%), while other variants sit on the standard Version 7.0 tier.
What 2026 federal tax credit and Lead RRP rules apply to Premium Vinyl (V-4500) SH/HS Fixed Direct Set?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How do building inspectors verify Premium Vinyl (V-4500) SH/HS Fixed Direct Set glass specs on job sites?
Match the NFRC thermal sticker for code JEL and line JEL-A-545 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Premium Vinyl (V-4500) SH/HS Fixed Direct Set come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)