JELD-WEN, inc. — 7500 Single Hung · Single Hung
JELD-WEN, inc. engineered the 7500 Single Hung Single Hung line for Northern, North-Central, South-Central, Southern, certifying 42,169 glass-spacer combinations from 0.14 to 0.32 U-Factor and 0.15 to 0.56 SHGC. Relative to other Vinyl models tracked under NFRC JEL, its minimum U-Factor is 0.05 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.14
- SHGC Range
- 0.15-0.56
- Certified Options
- 42,169
- Category Standing
- #72 of 1,352
How does JELD-WEN, inc. 7500 Single Hung compare thermally against Window peers?
JELD-WEN, inc. 7500 Single Hung achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 61 certified JELD-WEN, inc. series, this Single Hung offers a 0.18 U-Factor adjustment span between 0.32 entry options and 0.14 top-performing glazing. Category standing is #72/1,352 (tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%).
Climate coverage for JELD-WEN, inc. 7500 Single Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 8,400 configurations meet ENERGY STAR Most Efficient criteria while 17,567 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 84.0 BTU/hr (-36.4% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2026-08-06.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 42,169 certified glazing combinations for 7500 Single Hung (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 17,567 packages (4,307 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 23,406 packages (5,581 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 17,148 packages (3,223 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 23,890 packages (5,679 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| MI Windows and Doors, LLC — 3075/3065 Direct Set Picture Window | Vinyl | 0.14 | 0.09 | 35,308 |
| Milgard Manufacturing, Inc. — 8340T2 Picture Window | Vinyl | 0.14 | 0.09 | 35,182 |
| Simonton Building Products, Inc. - Simonton Windows — 07-09 / 07-10 / 07-20 / 07-75 PW | Vinyl | 0.14 | 0.08 | 52,166 |
| Wincore Window Company, LLC — 7700, 8400, 8800 Picture Window | Vinyl | 0.14 | 0.08 | 28,216 |
| Associated Materials, Inc. — A681/691 Awning | Vinyl | 0.14 | 0.05 | 60,157 |
What other certified series does JELD-WEN, inc. produce?
Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
7500 Series Horizontal Slider
U-Factor 0.14–0.32 · 42,001 certified options.
Premium Vinyl (V-4500) Casement Fixed Direct Set
U-Factor 0.14–0.32 · 2,573 certified options.
Siteline Clad Wood (W-5500) Fixed Direct Set Geo
U-Factor 0.14–0.32 · 4,582 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. 7500 Single Hung appear below.
What thermal performance numbers separate JELD-WEN, inc. 7500 Single Hung from peers?
Testing puts JELD-WEN, inc. 7500 Single Hung at rank #72 of 1,352 Window entries with U 0.14 to 0.32 across 42,169 configurations. Solar heat gain ranges between 0.15 and 0.56 across Northern, North-Central, South-Central, Southern.
Does JELD-WEN, inc. 7500 Single Hung qualify for the ENERGY STAR Northern Zone?
Prescriptive Northern compliance covers 17,567 7500 Single Hung packages (U floor 0.14, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.
What BTU/hr heat transfer results from 7500 Single Hung's 0.14 minimum U-Factor?
Using NFRC JEL U-Factor 0.14, a 15 sq ft Single-Hung (VSSH) assembly conducts 84.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-48.0 BTU/hr margin).
Who should NOT choose JELD-WEN, inc. 7500 Single Hung for a residential project?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 7500 Single Hung options exceeding U 0.22. Additionally, do not order Single-Hung (VSSH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
How many 7500 Single Hung glazing packages pass Southern solar-heat rules?
Yes, 7500 Single Hung holds 23,890 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.15 SHGC in cooling climates.
What glazing share inside 7500 Single Hung qualifies as Most Efficient?
EPA lists 8,400 Most Efficient options (19.9% share) inside JELD-WEN, inc. 7500 Single Hung, out of 42,169 total Version 7.0 entries.
Do 2026 7500 Single Hung installations qualify for IRS Section 25C tax credits?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
Where are NFRC and IGCC identification marks located on 7500 Single Hung?
Confirm both the paper NFRC label and permanent corner glass etch match line JEL-A-1009 and NFRC ID JEL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. 7500 Single Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)