Skip to main content
Window · Vinyl Frame NFRC JEL · Product Line JEL-A-870 ENERGY STAR Most Efficient Eligible

JELD-WEN, inc. — Premium Vinyl (V-4500) Casement Fixed Direct Set · Picture Window

Positioning #72/1,352 in certified Window, JELD-WEN, inc. Premium Vinyl (V-4500) Casement Fixed Direct Set pairs Vinyl frame construction with 2,573 glazing options rated between 0.13 and 0.53 SHGC across Northern, North-Central, South-Central, Southern. Across 61 certified JELD-WEN, inc. product families, its thermal resistance spans 0.14 to 0.32 U-Factor and the line includes 176 ENERGY STAR Most Efficient packages (6.8% of line).

Min U-Factor
0.14
SHGC Range
0.13-0.53
Certified Options
2,573
Category Standing
#72 of 1,352

How does JELD-WEN, inc. Premium Vinyl (V-4500) Casement Fixed Direct Set compare thermally against Window peers?

JELD-WEN, inc. Premium Vinyl (V-4500) Casement Fixed Direct Set achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Premium Vinyl (V-4500) Casement Fixed Direct SetHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Premium Vinyl (V-4500) Casement Fixed Direct Set (U 0.14).249<=0.15This model: U 0.143140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Premium Vinyl (V-4500) Casement Fixed Direct Set Cohort StandingMin U-Factor 0.14 stands at rank #72 of 1,352, outperforming 90.0% of peers.Min U-Factor 0.14Rank #72 of 1,352 (90.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 61 certified JELD-WEN, inc. series, this Picture Window offers a 0.18 U-Factor adjustment span between 0.32 entry options and 0.14 top-performing glazing. Category standing is #72/1,352 (tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%).

Climate coverage for JELD-WEN, inc. Premium Vinyl (V-4500) Casement Fixed Direct Set spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 176 configurations meet ENERGY STAR Most Efficient criteria while 420 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.14 U-Factor yields 84.0 BTU/hr transfer (-48.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2026-10-30 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,573 certified glazing combinations for Premium Vinyl (V-4500) Casement Fixed Direct Set (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 420 packages (86 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 814 packages (104 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,175 packages (55 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,070 packages (117 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Premium Vinyl (V-4500) Casement Fixed Direct Set appear below.

How efficient is JELD-WEN, inc. Premium Vinyl (V-4500) Casement Fixed Direct Set compared with peer Window models?

Testing puts JELD-WEN, inc. Premium Vinyl (V-4500) Casement Fixed Direct Set at rank #72 of 1,352 Window entries with U 0.14 to 0.32 across 2,573 configurations. Solar heat gain ranges between 0.13 and 0.53 across Northern, North-Central, South-Central, Southern.

How does JELD-WEN, inc. Premium Vinyl (V-4500) Casement Fixed Direct Set satisfy Version 7.0 Northern criteria?

Cold-climate buyers get 420 compliant Northern packages inside Premium Vinyl (V-4500) Casement Fixed Direct Set, reaching down to U 0.14. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How much winter heat loss does Premium Vinyl (V-4500) Casement Fixed Direct Set conduct across a 15 sq ft opening?

At U 0.14, a standard 3x5 ft (15 sq ft) Premium Vinyl (V-4500) Casement Fixed Direct Set opening transfers 84.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -48.0 BTU/hr difference.

Which situations make Premium Vinyl (V-4500) Casement Fixed Direct Set the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Premium Vinyl (V-4500) Casement Fixed Direct Set options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Does Premium Vinyl (V-4500) Casement Fixed Direct Set meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 2,070 Premium Vinyl (V-4500) Casement Fixed Direct Set options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.13 rather than higher 0.53 glass.

What glazing share inside Premium Vinyl (V-4500) Casement Fixed Direct Set qualifies as Most Efficient?

Not every package qualifies: 176 of 2,573 Premium Vinyl (V-4500) Casement Fixed Direct Set glazing builds earn Most Efficient recognition (6.8%), while other variants sit on the standard Version 7.0 tier.

Can homeowners claim Form 5695 credits on JELD-WEN, inc. Premium Vinyl (V-4500) Casement Fixed Direct Set in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Premium Vinyl (V-4500) Casement Fixed Direct Set installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC JEL and product line JEL-A-870 on delivery?

Inspectors match the temporary NFRC sticker (U 0.14-0.32, SHGC 0.13-0.53) against permit drawings for line JEL-A-870. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Premium Vinyl (V-4500) Casement Fixed Direct Set come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros