Window · Vinyl Frame NFRC MEI · Product Line MEI-A-225 ENERGY STAR Most Efficient Eligible

MI Windows and Doors, LLC — 1615T Polyvinyl Chloride (PVC) Transom · Transom

With a minimum U-Factor of 0.14—-0.06 compared against the 0.20 Window median—MI Windows and Doors, LLC 1615T Polyvinyl Chloride (PVC) Transom spans 3,234 tested options across Northern, North-Central, South-Central, Southern up to 0.31 U-Factor. Carrying NFRC CPD code MEI, the Vinyl assembly includes 1,165 ENERGY STAR Most Efficient packages (36.0% of line) and offers SHGC packages between 0.07 and 0.52.

Min U-Factor
0.14
SHGC Range
0.07-0.52
Certified Options
3,234
Category Standing
#72 of 1,352

How does MI Windows and Doors, LLC 1615T Polyvinyl Chloride (PVC) Transom compare thermally against Window peers?

MI Windows and Doors, LLC 1615T Polyvinyl Chloride (PVC) Transom achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1615T Polyvinyl Chloride (PVC) TransomHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 1615T Polyvinyl Chloride (PVC) Transom (U 0.14).249<=0.15This model: U 0.143140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1615T Polyvinyl Chloride (PVC) Transom Cohort StandingMin U-Factor 0.14 stands at rank #72 of 1,352, outperforming 90.0% of peers.Min U-Factor 0.14Rank #72 of 1,352 (90.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 1615T Polyvinyl Chloride (PVC) Transom is 0.06 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.14-0.31.

Mapping NFRC SHGC values (0.07 to 0.52) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 1,165 configurations meet ENERGY STAR Most Efficient criteria while 972 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 84.0 BTU/hr (-36.4% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-09-11 and cert timestamp 2024-04-12.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,234 certified glazing combinations for 1615T Polyvinyl Chloride (PVC) Transom (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 972 packages (316 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 2,180 packages (729 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 2,194 packages (576 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,416 packages (943 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
EnergyWall Window — 7400/3100 Picture Window Vinyl 0.14 0.15 3,407
Polaris Windows and Doors — 7400/3100 Picture Window Vinyl 0.14 0.15 3,407
Harvey Industries, Inc. — Axio Tilt Turn Window Vinyl 0.14 0.14 3,474
Milgard Manufacturing, Inc. — 12710 Fixed Vinyl 0.14 0.10 3,568
JELD-WEN, inc. — Premium Vinyl (V-4500) Casement Fixed Direct Set Vinyl 0.14 0.13 2,573

What other certified series does MI Windows and Doors, LLC produce?

Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 1615T Polyvinyl Chloride (PVC) Transom appear below.

What U-Factor and SHGC range does MI Windows and Doors, LLC 1615T Polyvinyl Chloride (PVC) Transom achieve?

EPA ENERGY STAR v7.0 records 3,234 configurations for MI Windows and Doors, LLC 1615T Polyvinyl Chloride (PVC) Transom covering Northern, North-Central, South-Central, Southern, dropping down to U 0.14 versus a 0.20 Window median. Only 1,165 options earn Most Efficient status.

Is 1615T Polyvinyl Chloride (PVC) Transom approved for Northern Zone heating climates?

Cold-climate buyers get 972 compliant Northern packages inside 1615T Polyvinyl Chloride (PVC) Transom, reaching down to U 0.14. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.31 options.

What conductive BTU/hr difference separates 1615T Polyvinyl Chloride (PVC) Transom from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.14 U-Factor yields 84.0 BTU/hr conductive transfer (-36.4% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip MI Windows and Doors, LLC 1615T Polyvinyl Chloride (PVC) Transom and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1615T Polyvinyl Chloride (PVC) Transom options exceeding U 0.22. Additionally, do not order Fixed Transom (FXTR) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does 1615T Polyvinyl Chloride (PVC) Transom meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, 1615T Polyvinyl Chloride (PVC) Transom holds 2,416 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.07 SHGC in cooling climates.

What glazing share inside 1615T Polyvinyl Chloride (PVC) Transom qualifies as Most Efficient?

Not every package qualifies: 1,165 of 3,234 1615T Polyvinyl Chloride (PVC) Transom glazing builds earn Most Efficient recognition (36.0%), while other variants sit on the standard Version 7.0 tier.

What federal compliance checks govern 2026 1615T Polyvinyl Chloride (PVC) Transom window swaps?

Any 1615T Polyvinyl Chloride (PVC) Transom purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

What permanent glass etch marks verify 1615T Polyvinyl Chloride (PVC) Transom after sticker removal?

Verify NFRC ID MEI and series MEI-A-225 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 1615T Polyvinyl Chloride (PVC) Transom come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros