MI Windows and Doors, LLC — 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window · Picture Window
EPA ENERGY STAR Version 7.0 certifies 6,920 variants inside MI Windows and Doors, LLC 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window, combining Vinyl frame construction with U-Factors spanning 0.13 to 0.32 and SHGC 0.08 to 0.51. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #36 of 1,352 among 1,352 Window families and posts 0.06 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.
- Min U-Factor
- 0.13
- SHGC Range
- 0.08-0.51
- Certified Options
- 6,920
- Category Standing
- #36 of 1,352
How does MI Windows and Doors, LLC 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window compare thermally against Window peers?
MI Windows and Doors, LLC 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window is 0.07 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.13-0.32.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 2,322 configurations meet ENERGY STAR Most Efficient criteria while 2,339 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.13 U-Factor yields 78.0 BTU/hr transfer (-54.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-09-11 licensing and 2024-09-11 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 6,920 certified glazing combinations for 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 2,339 packages (446 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 5,250 packages (1,166 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 4,305 packages (960 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 4,808 packages (2,056 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| EnergyWall Window — 8605/3205 Casement Picture Window | Vinyl | 0.13 | 0.16 | 3,472 |
| Polaris Windows and Doors — 8605/3205 Casement Picture Window | Vinyl | 0.13 | 0.16 | 3,472 |
| Associated Materials, Inc. — A780/A790/ S780 Picture | Vinyl | 0.13 | 0.07 | 3,066 |
| Seaway Manufacturing Corporation — Lighthouse/Commander Casement Fixed | Vinyl | 0.13 | 0.12 | 2,119 |
| Euroline Windows Inc. — Energeto Neo-76 Picture Window | Vinyl | 0.13 | 0.15 | 2,041 |
What other certified series does MI Windows and Doors, LLC produce?
Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.12–0.32 · 8,307 certified options.
1615T Polyvinyl Chloride (PVC) Transom
U-Factor 0.14–0.31 · 3,234 certified options.
3075/3065 Direct Set Picture Window
U-Factor 0.14–0.32 · 35,308 certified options.
SR CASE PW Vinyl Fixed Window
U-Factor 0.14–0.31 · 5,254 certified options.
1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.15–0.32 · 11,774 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window appear below.
What U-Factor and SHGC range does MI Windows and Doors, LLC 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window achieve?
Testing puts MI Windows and Doors, LLC 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window at rank #36 of 1,352 Window entries with U 0.13 to 0.32 across 6,920 configurations. Solar heat gain ranges between 0.08 and 0.51 across Northern, North-Central, South-Central, Southern.
Can homeowners install 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window in cold Northern ENERGY STAR counties?
Prescriptive Northern compliance covers 2,339 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window packages (U floor 0.13, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.
What BTU/hr heat transfer results from 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window's 0.13 minimum U-Factor?
At U 0.13, a standard 3x5 ft (15 sq ft) 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window opening transfers 78.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -54.0 BTU/hr difference.
Who should NOT choose MI Windows and Doors, LLC 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window for a residential project?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Can you install MI Windows and Doors, LLC 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window in Southern or South-Central zones?
Warm-climate homeowners have 4,808 Southern-approved options within 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window spanning SHGC down to 0.08. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Which package tier in 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window holds Most Efficient recognition?
EPA lists 2,322 Most Efficient options (33.6% share) inside MI Windows and Doors, LLC 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window, out of 6,920 total Version 7.0 entries.
What 2026 federal tax credit and Lead RRP rules apply to 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How do building inspectors verify 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window glass specs on job sites?
Verify NFRC ID MEI and series MEI-A-172 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)