Skip to main content
Window · Vinyl Frame NFRC ASO · Product Line ASO-A-99 ENERGY STAR Most Efficient Eligible

Associated Materials, Inc. — A780/A790/ S780 Picture · Picture Window

Positioning #36/1,352 in certified Window, Associated Materials, Inc. A780/A790/ S780 Picture pairs Vinyl frame construction with 3,066 glazing options rated between 0.07 and 0.56 SHGC across Northern, North-Central, South-Central, Southern. Across 34 certified Associated Materials, Inc. product families, its thermal resistance spans 0.13 to 0.32 U-Factor and the line includes 909 ENERGY STAR Most Efficient packages (29.6% of line).

Min U-Factor
0.13
SHGC Range
0.07-0.56
Certified Options
3,066
Category Standing
#36 of 1,352

How does Associated Materials, Inc. A780/A790/ S780 Picture compare thermally against Window peers?

Associated Materials, Inc. A780/A790/ S780 Picture achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. A780/A790/ S780 PictureHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing A780/A790/ S780 Picture (U 0.13).249<=0.15This model: U 0.133140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

A780/A790/ S780 Picture Cohort StandingMin U-Factor 0.13 stands at rank #36 of 1,352, outperforming 94.7% of peers.Min U-Factor 0.13Rank #36 of 1,352 (94.7% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across A780/A790/ S780 Picture spans 3,066 NFRC test records (ASO), ranking #36 of 1,352 Window families (tied with 35 others at 0.13, more insulating than 94.7% of Window lines, top 5.3%). Its 0.13 thermal floor compares at -0.06 against the Vinyl median (0.19).

Mapping NFRC SHGC values (0.07 to 0.56) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 909 configurations meet ENERGY STAR Most Efficient criteria while 973 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors ASO to 2025-09-29 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 78.0 BTU/hr conductive loss (-40.9% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,066 certified glazing combinations for A780/A790/ S780 Picture (NFRC ASO) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 973 packages (479 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,431 packages (698 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,564 packages (433 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,251 packages (594 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Associated Materials, Inc. produce?

Compare other active Associated Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Associated Materials, Inc. A780/A790/ S780 Picture appear below.

How well does A780/A790/ S780 Picture by Associated Materials, Inc. insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 3,066 configurations for Associated Materials, Inc. A780/A790/ S780 Picture covering Northern, North-Central, South-Central, Southern, dropping down to U 0.13 versus a 0.20 Window median. Only 909 options earn Most Efficient status.

Can homeowners install A780/A790/ S780 Picture in cold Northern ENERGY STAR counties?

Yes. 973 packages in Associated Materials, Inc. A780/A790/ S780 Picture clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

What conductive BTU/hr difference separates A780/A790/ S780 Picture from the 0.22 Northern rule?

At U 0.13, a standard 3x5 ft (15 sq ft) A780/A790/ S780 Picture opening transfers 78.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -54.0 BTU/hr difference.

When should a buyer skip Associated Materials, Inc. A780/A790/ S780 Picture and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on A780/A790/ S780 Picture options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Can you install Associated Materials, Inc. A780/A790/ S780 Picture in Southern or South-Central zones?

Yes, A780/A790/ S780 Picture holds 2,251 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.07 SHGC in cooling climates.

Are all 3,066 A780/A790/ S780 Picture configurations ENERGY STAR Most Efficient?

No. Exactly 909 of 3,066 configurations (29.6%) earn ENERGY STAR Most Efficient status in A780/A790/ S780 Picture; the remaining standard v7.0 options pass base zone limits only.

How do the 25C sunset and pre-1978 Lead RRP rules affect A780/A790/ S780 Picture?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify A780/A790/ S780 Picture after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code ASO and product line ASO-A-99, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Associated Materials, Inc. A780/A790/ S780 Picture come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros