Skip to main content
Window · Vinyl Frame NFRC ASO · Product Line ASO-A-105 ENERGY STAR Most Efficient Eligible

Associated Materials, Inc. — A280/A580/S280/S580/A390 Fixed · Picture Window

Associated Materials, Inc. engineered the A280/A580/S280/S580/A390 Fixed Picture Window line for Northern, North-Central, South-Central, Southern, certifying 12,249 glass-spacer combinations from 0.12 to 0.32 U-Factor and 0.07 to 0.56 SHGC. Relative to other Vinyl models tracked under NFRC ASO, its minimum U-Factor is 0.07 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.12
SHGC Range
0.07-0.56
Certified Options
12,249
Category Standing
#19 of 1,352

How does Associated Materials, Inc. A280/A580/S280/S580/A390 Fixed compare thermally against Window peers?

Associated Materials, Inc. A280/A580/S280/S580/A390 Fixed achieves a 0.12 thermal floor across Window lines, placing #19 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. A280/A580/S280/S580/A390 FixedHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing A280/A580/S280/S580/A390 Fixed (U 0.12).249<=0.15This model: U 0.123140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

A280/A580/S280/S580/A390 Fixed Cohort StandingMin U-Factor 0.12 stands at rank #19 of 1,352, outperforming 97.4% of peers.Min U-Factor 0.12Rank #19 of 1,352 (97.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across A280/A580/S280/S580/A390 Fixed spans 12,249 NFRC test records (ASO), ranking #19 of 1,352 Window families (tied with 16 others at 0.12, more insulating than 97.4% of Window lines, top 2.6%). Its 0.12 thermal floor compares at -0.07 against the Vinyl median (0.19).

Regional qualification covers Northern, North-Central, South-Central, Southern. 4,183 configurations meet ENERGY STAR Most Efficient criteria while 4,384 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 72.0 BTU/hr (-45.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2025-11-19.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 12,249 certified glazing combinations for A280/A580/S280/S580/A390 Fixed (NFRC ASO) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 4,384 packages (2,398 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 7,280 packages (3,452 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 5,964 packages (1,786 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 8,400 packages (2,517 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.12 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Associated Materials, Inc. produce?

Compare other active Associated Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Associated Materials, Inc. A280/A580/S280/S580/A390 Fixed appear below.

What thermal performance numbers separate Associated Materials, Inc. A280/A580/S280/S580/A390 Fixed from peers?

Testing puts Associated Materials, Inc. A280/A580/S280/S580/A390 Fixed at rank #19 of 1,352 Window entries with U 0.12 to 0.32 across 12,249 configurations. Solar heat gain ranges between 0.07 and 0.56 across Northern, North-Central, South-Central, Southern.

Which glazing options in Associated Materials, Inc. A280/A580/S280/S580/A390 Fixed meet Northern climate limits?

Cold-climate buyers get 4,384 compliant Northern packages inside A280/A580/S280/S580/A390 Fixed, reaching down to U 0.12. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How do you calculate winter heat conduction for Associated Materials, Inc. A280/A580/S280/S580/A390 Fixed?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), A280/A580/S280/S580/A390 Fixed at U 0.12 conducts 72.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Associated Materials, Inc. A280/A580/S280/S580/A390 Fixed and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on A280/A580/S280/S580/A390 Fixed options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

How many A280/A580/S280/S580/A390 Fixed glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 8,400 Southern-approved options within A280/A580/S280/S580/A390 Fixed spanning SHGC down to 0.07. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in A280/A580/S280/S580/A390 Fixed holds Most Efficient recognition?

No. Exactly 4,183 of 12,249 configurations (34.1%) earn ENERGY STAR Most Efficient status in A280/A580/S280/S580/A390 Fixed; the remaining standard v7.0 options pass base zone limits only.

What 2026 federal tax credit and Lead RRP rules apply to A280/A580/S280/S580/A390 Fixed?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 A280/A580/S280/S580/A390 Fixed installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on A280/A580/S280/S580/A390 Fixed?

Confirm both the paper NFRC label and permanent corner glass etch match line ASO-A-105 and NFRC ID ASO before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Associated Materials, Inc. A280/A580/S280/S580/A390 Fixed come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros