Associated Materials, Inc. — A680 Fixed Sash · Picture Window
Associated Materials, Inc. engineered the A680 Fixed Sash Picture Window line for Northern, North-Central, South-Central, Southern, certifying 28,687 glass-spacer combinations from 0.13 to 0.32 U-Factor and 0.05 to 0.56 SHGC. Relative to other Vinyl models tracked under NFRC ASO, its minimum U-Factor is 0.06 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.13
- SHGC Range
- 0.05-0.56
- Certified Options
- 28,687
- Category Standing
- #36 of 1,352
How does Associated Materials, Inc. A680 Fixed Sash compare thermally against Window peers?
Associated Materials, Inc. A680 Fixed Sash achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across A680 Fixed Sash spans 28,687 NFRC test records (ASO), ranking #36 of 1,352 Window families (tied with 35 others at 0.13, more insulating than 94.7% of Window lines, top 5.3%). Its 0.13 thermal floor compares at -0.06 against the Vinyl median (0.19).
Regional qualification covers Northern, North-Central, South-Central, Southern. 16,086 configurations meet ENERGY STAR Most Efficient criteria while 12,948 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-04-12. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.13 conducts 78.0 BTU/hr (-54.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 28,687 certified glazing combinations for A680 Fixed Sash (NFRC ASO) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 12,948 packages (7,459 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 21,872 packages (14,391 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 17,457 packages (10,140 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 20,972 packages (11,835 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| PGT Industries — PW5420/5520 | Vinyl | 0.13 | 0.08 | 23,690 |
| Milgard Manufacturing, Inc. — 8521T2.8531T2.8571T2 Casement Fixed | Vinyl | 0.13 | 0.09 | 23,185 |
| Milgard Manufacturing, Inc. — 8541T2 Casement Fixed | Vinyl | 0.13 | 0.09 | 37,615 |
| Great Lakes Window, Inc. — ComfortSmart/ecoSmart - Special Shapes Fixed Window | Vinyl | 0.13 | 0.15 | 18,122 |
| MI Windows and Doors, LLC — 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window | Vinyl | 0.13 | 0.08 | 6,920 |
What other certified series does Associated Materials, Inc. produce?
Compare other active Associated Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
A280/A580/S280/S580/A390 Fixed
U-Factor 0.12–0.32 · 12,249 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Associated Materials, Inc. A680 Fixed Sash appear below.
Where does Associated Materials, Inc. A680 Fixed Sash stand thermally among ENERGY STAR Window lines?
Across 28,687 tested NFRC glazing configurations, Associated Materials, Inc. A680 Fixed Sash with Vinyl framing and Fixed Window (FIXD) style reaches a 0.13 minimum U-Factor and 0.05-0.56 SHGC band. It places #36 among 1,352 Window series—top 5.3%.
How does Associated Materials, Inc. A680 Fixed Sash satisfy Version 7.0 Northern criteria?
Cold-climate buyers get 12,948 compliant Northern packages inside A680 Fixed Sash, reaching down to U 0.13. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.
What BTU/hr heat transfer results from A680 Fixed Sash's 0.13 minimum U-Factor?
Using NFRC ASO U-Factor 0.13, a 15 sq ft Fixed Window (FIXD) assembly conducts 78.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-54.0 BTU/hr margin).
When should a buyer skip Associated Materials, Inc. A680 Fixed Sash and compare alternatives?
Do not specify A680 Fixed Sash without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on A680 Fixed Sash options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Can you install Associated Materials, Inc. A680 Fixed Sash in Southern or South-Central zones?
Yes, A680 Fixed Sash holds 20,972 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.05 SHGC in cooling climates.
Are all 28,687 A680 Fixed Sash configurations ENERGY STAR Most Efficient?
Within A680 Fixed Sash, 56.1% (16,086 of 28,687) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.
How do the 25C sunset and pre-1978 Lead RRP rules affect A680 Fixed Sash?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 A680 Fixed Sash installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
How do building inspectors verify A680 Fixed Sash glass specs on job sites?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code ASO and product line ASO-A-106, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Associated Materials, Inc. A680 Fixed Sash come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)