Skip to main content
Window · Vinyl Frame NFRC ASO · Product Line ASO-A-91 ENERGY STAR Most Efficient Eligible

Associated Materials, Inc. — 3004 Picture Window · Picture Window

Associated Materials, Inc. 3004 Picture Window is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.13 across 43,046 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #36 of 1,352 in Window, its thermal floor is 0.07 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.06 to 0.55.

Min U-Factor
0.13
SHGC Range
0.06-0.55
Certified Options
43,046
Category Standing
#36 of 1,352

How does Associated Materials, Inc. 3004 Picture Window compare thermally against Window peers?

Associated Materials, Inc. 3004 Picture Window achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 3004 Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 3004 Picture Window (U 0.13).249<=0.15This model: U 0.133140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

3004 Picture Window Cohort StandingMin U-Factor 0.13 stands at rank #36 of 1,352, outperforming 94.7% of peers.Min U-Factor 0.13Rank #36 of 1,352 (94.7% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Associated Materials, Inc. 3004 Picture Window at rank #36 of 1,352 (tied with 35 others at 0.13, more insulating than 94.7% of Window lines, top 5.3%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.06-0.55 band.

Mapping NFRC SHGC values (0.06 to 0.55) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 19,886 configurations meet ENERGY STAR Most Efficient criteria while 18,677 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-02-21 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 78.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 43,046 certified glazing combinations for 3004 Picture Window (NFRC ASO) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 18,677 packages (9,443 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 33,600 packages (15,970 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 24,098 packages (10,216 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 28,258 packages (14,132 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Associated Materials, Inc. produce?

Compare other active Associated Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Associated Materials, Inc. 3004 Picture Window appear below.

What thermal performance numbers separate Associated Materials, Inc. 3004 Picture Window from peers?

Testing puts Associated Materials, Inc. 3004 Picture Window at rank #36 of 1,352 Window entries with U 0.13 to 0.32 across 43,046 configurations. Solar heat gain ranges between 0.06 and 0.55 across Northern, North-Central, South-Central, Southern.

Does Associated Materials, Inc. 3004 Picture Window qualify for the ENERGY STAR Northern Zone?

Yes, 18,677 packages satisfy Northern ENERGY STAR Version 7.0 rules in 3004 Picture Window. Pairing multi-pane insulation down to 0.13 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How do you calculate winter heat conduction for Associated Materials, Inc. 3004 Picture Window?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.13 U-Factor yields 78.0 BTU/hr conductive transfer (-40.9% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make 3004 Picture Window the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 3004 Picture Window options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in 3004 Picture Window?

Across Northern, North-Central, South-Central, Southern, 28,258 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Associated Materials, Inc. 3004 Picture Window, while total line SHGC reaches 0.55 in colder packages.

Which package tier in 3004 Picture Window holds Most Efficient recognition?

Within 3004 Picture Window, 46.2% (19,886 of 43,046) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

How do the 25C sunset and pre-1978 Lead RRP rules affect 3004 Picture Window?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 3004 Picture Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do building inspectors verify 3004 Picture Window glass specs on job sites?

Verify NFRC ID ASO and series ASO-A-91 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Associated Materials, Inc. 3004 Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros