Window · Vinyl Frame NFRC ASO · Product Line ASO-A-107 ENERGY STAR Most Efficient Eligible

Associated Materials, Inc. — A682/692 Casement · Casement Windows

Associated Materials, Inc. A682/692 Casement is a Casement Windows assembly with a Vinyl frame that reaches a minimum U-Factor of 0.14 across 60,748 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #72 of 1,352 in Window, its thermal floor is 0.06 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.05 to 0.47.

Min U-Factor
0.14
SHGC Range
0.05-0.47
Certified Options
60,748
Category Standing
#72 of 1,352

How does Associated Materials, Inc. A682/692 Casement compare thermally against Window peers?

Associated Materials, Inc. A682/692 Casement achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. A682/692 CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing A682/692 Casement (U 0.14).249<=0.15This model: U 0.143140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

A682/692 Casement Cohort StandingMin U-Factor 0.14 stands at rank #72 of 1,352, outperforming 90.0% of peers.Min U-Factor 0.14Rank #72 of 1,352 (90.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 34 certified Associated Materials, Inc. series, this Casement Windows offers a 0.18 U-Factor adjustment span between 0.32 entry options and 0.14 top-performing glazing. Category standing is #72/1,352 (tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%).

Climate coverage for Associated Materials, Inc. A682/692 Casement spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 29,665 configurations meet ENERGY STAR Most Efficient criteria while 17,897 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors ASO to 2024-01-12 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 84.0 BTU/hr conductive loss (-36.4% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 60,748 certified glazing combinations for A682/692 Casement (NFRC ASO) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 17,897 packages (6,966 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 41,299 packages (22,031 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 45,702 packages (19,892 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 54,720 packages (27,526 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Associated Materials, Inc. produce?

Compare other active Associated Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Associated Materials, Inc. A682/692 Casement appear below.

How well does A682/692 Casement by Associated Materials, Inc. insulate relative to Window benchmarks?

Built with Vinyl framing in Casement Single-Vent (CSSV) style, Associated Materials, Inc. A682/692 Casement offers 60,748 Version 7.0 configurations from U 0.14 up to 0.32, posting -0.06 against the Window median of 0.20 with 29,665 Most Efficient picks.

Does Associated Materials, Inc. A682/692 Casement qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 17,897 compliant Northern packages inside A682/692 Casement, reaching down to U 0.14. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How much winter heat loss does A682/692 Casement conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.14 U-Factor yields 84.0 BTU/hr conductive transfer (-36.4% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What are the practical limitations of specifying A682/692 Casement?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on A682/692 Casement options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in A682/692 Casement?

Yes. 54,720 Southern-certified options inside Associated Materials, Inc. A682/692 Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.47 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in A682/692 Casement holds Most Efficient recognition?

Not every package qualifies: 29,665 of 60,748 A682/692 Casement glazing builds earn Most Efficient recognition (48.8%), while other variants sit on the standard Version 7.0 tier.

How do the 25C sunset and pre-1978 Lead RRP rules affect A682/692 Casement?

Any A682/692 Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC ASO and product line ASO-A-107 on delivery?

Match the NFRC thermal sticker for code ASO and line ASO-A-107 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Associated Materials, Inc. A682/692 Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros