Skip to main content
Window · Vinyl Frame NFRC SBP · Product Line SBP-A-43 ENERGY STAR Most Efficient Eligible

Simonton Building Products, Inc. - Simonton Windows — 07-09 / 07-10 / 07-20 / 07-75 PW · Picture Window

With a minimum U-Factor of 0.14—-0.06 compared against the 0.20 Window median—Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 PW spans 52,166 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code SBP, the Vinyl assembly includes 8,055 ENERGY STAR Most Efficient packages (15.4% of line) and offers SHGC packages between 0.08 and 0.56.

Min U-Factor
0.14
SHGC Range
0.08-0.56
Certified Options
52,166
Category Standing
#72 of 1,352

How does Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 PW compare thermally against Window peers?

Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 PW achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 07-09 / 07-10 / 07-20 / 07-75 PWHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 07-09 / 07-10 / 07-20 / 07-75 PW (U 0.14).249<=0.15This model: U 0.143140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

07-09 / 07-10 / 07-20 / 07-75 PW Cohort StandingMin U-Factor 0.14 stands at rank #72 of 1,352, outperforming 90.0% of peers.Min U-Factor 0.14Rank #72 of 1,352 (90.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 07-09 / 07-10 / 07-20 / 07-75 PW spans 52,166 NFRC test records (SBP), ranking #72 of 1,352 Window families (tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%). Its 0.14 thermal floor compares at -0.05 against the Vinyl median (0.19).

Climate coverage for Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 PW spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 8,055 configurations meet ENERGY STAR Most Efficient criteria while 12,011 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors SBP to 2025-04-25 certification (FENSTAR issued 2018-08-23). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 84.0 BTU/hr conductive loss (-36.4% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 52,166 certified glazing combinations for 07-09 / 07-10 / 07-20 / 07-75 PW (NFRC SBP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 12,011 packages (544 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 28,313 packages (1,157 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 31,432 packages (969 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 39,098 packages (7,744 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Associated Materials, Inc. — A681/691 Awning Vinyl 0.14 0.05 60,157
Associated Materials, Inc. — A682/692 Casement Vinyl 0.14 0.05 60,748
JELD-WEN, inc. — 7500 Single Hung Vinyl 0.14 0.15 42,169
JELD-WEN, inc. — 7500 Series Horizontal Slider Vinyl 0.14 0.15 42,001
MI Windows and Doors, LLC — 3075/3065 Direct Set Picture Window Vinyl 0.14 0.09 35,308

What other certified series does Simonton Building Products, Inc. - Simonton Windows produce?

Compare other active Simonton Building Products, Inc. - Simonton Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 PW appear below.

What U-Factor and SHGC range does Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 PW achieve?

EPA ENERGY STAR v7.0 records 52,166 configurations for Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 PW covering Northern, North-Central, South-Central, Southern, dropping down to U 0.14 versus a 0.20 Window median. Only 8,055 options earn Most Efficient status.

Does Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 PW qualify for the ENERGY STAR Northern Zone?

Yes. 12,011 packages in Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 PW clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

What conductive BTU/hr difference separates 07-09 / 07-10 / 07-20 / 07-75 PW from the 0.22 Northern rule?

Using NFRC SBP U-Factor 0.14, a 15 sq ft Fixed Window (FIXD) assembly conducts 84.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-48.0 BTU/hr margin).

Which situations make 07-09 / 07-10 / 07-20 / 07-75 PW the wrong window or door choice?

Do not specify 07-09 / 07-10 / 07-20 / 07-75 PW without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 07-09 / 07-10 / 07-20 / 07-75 PW options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does 07-09 / 07-10 / 07-20 / 07-75 PW meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 39,098 07-09 / 07-10 / 07-20 / 07-75 PW options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.08 rather than higher 0.56 glass.

How many Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 PW variants earn ENERGY STAR Most Efficient?

Only 8,055 options out of 52,166 (15.4%) meet tighter Most Efficient U-Factor and SHGC thresholds in Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 PW, usually requiring triple-pane or upgraded Low-E coatings.

What 2026 federal tax credit and Lead RRP rules apply to 07-09 / 07-10 / 07-20 / 07-75 PW?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 07-09 / 07-10 / 07-20 / 07-75 PW retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do you cross-check NFRC SBP and product line SBP-A-43 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code SBP and product line SBP-A-43, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 PW come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros