Skip to main content
Window · Vinyl Frame NFRC SBP · Product Line SBP-A-53 ENERGY STAR Most Efficient Eligible

Simonton Building Products, Inc. - Simonton Windows — 325-325 AW · Awning (Projected)

EPA ENERGY STAR Version 7.0 certifies 13,343 variants inside Simonton Building Products, Inc. - Simonton Windows 325-325 AW, combining Vinyl frame construction with U-Factors spanning 0.17 to 0.32 and SHGC 0.09 to 0.46. Qualifying for Northern, North-Central, South-Central, Southern, this Awning, Projected family places #362 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.17
SHGC Range
0.09-0.46
Certified Options
13,343
Category Standing
#362 of 1,352

How does Simonton Building Products, Inc. - Simonton Windows 325-325 AW compare thermally against Window peers?

Simonton Building Products, Inc. - Simonton Windows 325-325 AW achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 325-325 AWHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 325-325 AW (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

325-325 AW Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Simonton Building Products, Inc. - Simonton Windows 325-325 AW standing at #362 of 1,352 certified Window product series, tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%. Comparing Vinyl profiles alone (median 0.19) shows -0.02 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.09 to 0.46) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 1,151 configurations meet ENERGY STAR Most Efficient criteria while 1,302 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-02-21 and FENSTAR license 2018-08-23 inside EPA Version 7.0 tables. Heat transfer computes to 102.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 13,343 certified glazing combinations for 325-325 AW (NFRC SBP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 1,302 packages (96 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 6,238 packages (272 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 9,190 packages (238 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 11,627 packages (1,117 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Quaker Window Products — V300 Casement Vinyl 0.17 0.09 11,114
Quaker Window Products — V300 Awning Vinyl 0.17 0.09 11,097
PGT Industries — AW5440/5540 Vinyl 0.17 0.08 16,848
PGT Industries — SH5400/5500 Vinyl 0.17 0.09 9,241
MI Windows and Doors, LLC — 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window Vinyl 0.17 0.06 17,618

What other certified series does Simonton Building Products, Inc. - Simonton Windows produce?

Compare other active Simonton Building Products, Inc. - Simonton Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Simonton Building Products, Inc. - Simonton Windows 325-325 AW appear below.

What U-Factor and SHGC range does Simonton Building Products, Inc. - Simonton Windows 325-325 AW achieve?

Across 13,343 tested NFRC glazing configurations, Simonton Building Products, Inc. - Simonton Windows 325-325 AW with Vinyl framing and Projected Awning (PRAW) style reaches a 0.17 minimum U-Factor and 0.09-0.46 SHGC band. It places #362 among 1,352 Window series—top 35.2%.

How does Simonton Building Products, Inc. - Simonton Windows 325-325 AW satisfy Version 7.0 Northern criteria?

Simonton Building Products, Inc. - Simonton Windows 325-325 AW supplies 1,302 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

How does a 3x5 ft 325-325 AW window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 325-325 AW at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What homeowner profiles are a poor match for Simonton Building Products, Inc. - Simonton Windows 325-325 AW?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 325-325 AW options exceeding U 0.22. Additionally, do not order Projected Awning (PRAW) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does 325-325 AW meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 11,627 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Simonton Building Products, Inc. - Simonton Windows 325-325 AW, while total line SHGC reaches 0.46 in colder packages.

Are all 13,343 325-325 AW configurations ENERGY STAR Most Efficient?

Not every package qualifies: 1,151 of 13,343 325-325 AW glazing builds earn Most Efficient recognition (8.6%), while other variants sit on the standard Version 7.0 tier.

Can homeowners claim Form 5695 credits on Simonton Building Products, Inc. - Simonton Windows 325-325 AW in 2026?

Any 325-325 AW purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Simonton Building Products, Inc. - Simonton Windows 325-325 AW units match permits?

Verify NFRC ID SBP and series SBP-A-53 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Simonton Building Products, Inc. - Simonton Windows 325-325 AW come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros