MI Windows and Doors, LLC — 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window · Double Hung
EPA ENERGY STAR Version 7.0 certifies 17,618 variants inside MI Windows and Doors, LLC 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window, combining Vinyl frame construction with U-Factors spanning 0.17 to 0.32 and SHGC 0.06 to 0.49. Qualifying for Northern, North-Central, South-Central, Southern, this Double Hung family places #362 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.
- Min U-Factor
- 0.17
- SHGC Range
- 0.06-0.49
- Certified Options
- 17,618
- Category Standing
- #362 of 1,352
How does MI Windows and Doors, LLC 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window compare thermally against Window peers?
MI Windows and Doors, LLC 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.32.
Climate coverage for MI Windows and Doors, LLC 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 2,449 configurations meet ENERGY STAR Most Efficient criteria while 2,836 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-09-11 licensing and 2024-02-29 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 17,618 certified glazing combinations for 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 2,836 packages (938 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 8,645 packages (1,800 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 10,699 packages (1,336 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 13,404 packages (1,889 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| PGT Industries — CA5440/5540 | Vinyl | 0.17 | 0.08 | 17,693 |
| PGT Industries — AW5440/5540 | Vinyl | 0.17 | 0.08 | 16,848 |
| Simonton Building Products, Inc. - Simonton Windows — 325-325 CA | Vinyl | 0.17 | 0.09 | 13,628 |
| Simonton Building Products, Inc. - Simonton Windows — 325-325 Double Slider | Vinyl | 0.17 | 0.08 | 21,756 |
| Simonton Building Products, Inc. - Simonton Windows — 325-325 AW | Vinyl | 0.17 | 0.09 | 13,343 |
What other certified series does MI Windows and Doors, LLC produce?
Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.12–0.32 · 8,307 certified options.
9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window
U-Factor 0.13–0.32 · 6,920 certified options.
1615T Polyvinyl Chloride (PVC) Transom
U-Factor 0.14–0.31 · 3,234 certified options.
3075/3065 Direct Set Picture Window
U-Factor 0.14–0.32 · 35,308 certified options.
SR CASE PW Vinyl Fixed Window
U-Factor 0.14–0.31 · 5,254 certified options.
1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.15–0.32 · 11,774 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window appear below.
What thermal performance numbers separate MI Windows and Doors, LLC 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window from peers?
EPA ENERGY STAR v7.0 records 17,618 configurations for MI Windows and Doors, LLC 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window covering Northern, North-Central, South-Central, Southern, dropping down to U 0.17 versus a 0.20 Window median. Only 2,449 options earn Most Efficient status.
How does MI Windows and Doors, LLC 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window satisfy Version 7.0 Northern criteria?
MI Windows and Doors, LLC 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window supplies 2,836 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.
How much winter heat loss does 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window conduct across a 15 sq ft opening?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 102.0 BTU/hr on 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window's lowest-U package (0.17), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
What homeowner profiles are a poor match for MI Windows and Doors, LLC 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
What Southern ENERGY STAR v7.0 options exist in 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window?
Across Northern, North-Central, South-Central, Southern, 13,404 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside MI Windows and Doors, LLC 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window, while total line SHGC reaches 0.49 in colder packages.
Are all 17,618 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window configurations ENERGY STAR Most Efficient?
Within 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window, 13.9% (2,449 of 17,618) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.
Do 2026 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window installations qualify for IRS Section 25C tax credits?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How do you cross-check NFRC MEI and product line MEI-A-217 on delivery?
Confirm both the paper NFRC label and permanent corner glass etch match line MEI-A-217 and NFRC ID MEI before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)