Window · Vinyl Frame NFRC MEI · Product Line MEI-A-234 ENERGY STAR Most Efficient Eligible

MI Windows and Doors, LLC — SR CASE PW Vinyl Fixed Window · Picture Window

Across 48 MI Windows and Doors, LLC certified families, SR CASE PW Vinyl Fixed Window supplies 5,254 Picture Window configurations starting at 0.14 U-Factor and 0.08 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.31 U-Factor and 0.51 SHGC. Its thermal floor ranks #72 of 1,352 category entries—0.06 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.14
SHGC Range
0.08-0.51
Certified Options
5,254
Category Standing
#72 of 1,352

How does MI Windows and Doors, LLC SR CASE PW Vinyl Fixed Window compare thermally against Window peers?

MI Windows and Doors, LLC SR CASE PW Vinyl Fixed Window achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. SR CASE PW Vinyl Fixed WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing SR CASE PW Vinyl Fixed Window (U 0.14).249<=0.15This model: U 0.143140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

SR CASE PW Vinyl Fixed Window Cohort StandingMin U-Factor 0.14 stands at rank #72 of 1,352, outperforming 90.0% of peers.Min U-Factor 0.14Rank #72 of 1,352 (90.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across SR CASE PW Vinyl Fixed Window spans 5,254 NFRC test records (MEI), ranking #72 of 1,352 Window families (tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%). Its 0.14 thermal floor compares at -0.05 against the Vinyl median (0.19).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 2,612 configurations meet ENERGY STAR Most Efficient criteria while 2,352 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-03-04 and FENSTAR license 2018-09-11 inside EPA Version 7.0 tables. Heat transfer computes to 84.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 5,254 certified glazing combinations for SR CASE PW Vinyl Fixed Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 2,352 packages (1,178 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 4,074 packages (2,003 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 3,134 packages (1,421 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 3,458 packages (1,871 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Great Day Improvements, LLC — 8200 Plus Picture Vinyl 0.14 0.17 4,219
Milgard Manufacturing, Inc. — 12710 Fixed Vinyl 0.14 0.10 3,568
Harvey Industries, Inc. — Axio Tilt Turn Window Vinyl 0.14 0.14 3,474
EnergyWall Window — 7400/3100 Picture Window Vinyl 0.14 0.15 3,407
Polaris Windows and Doors — 7400/3100 Picture Window Vinyl 0.14 0.15 3,407

What other certified series does MI Windows and Doors, LLC produce?

Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC SR CASE PW Vinyl Fixed Window appear below.

How well does SR CASE PW Vinyl Fixed Window by MI Windows and Doors, LLC insulate relative to Window benchmarks?

MI Windows and Doors, LLC SR CASE PW Vinyl Fixed Window spans 5,254 certified configurations with U-Factors between 0.14 and 0.31 and SHGC values from 0.08 to 0.51. Ranked #72 of 1,352 Window families, it carries 2,612 Most Efficient options.

Which glazing options in MI Windows and Doors, LLC SR CASE PW Vinyl Fixed Window meet Northern climate limits?

Cold-climate buyers get 2,352 compliant Northern packages inside SR CASE PW Vinyl Fixed Window, reaching down to U 0.14. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.31 options.

How much winter heat loss does SR CASE PW Vinyl Fixed Window conduct across a 15 sq ft opening?

Using NFRC MEI U-Factor 0.14, a 15 sq ft Fixed Window (FIXD) assembly conducts 84.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-48.0 BTU/hr margin).

What are the practical limitations of specifying SR CASE PW Vinyl Fixed Window?

Cold-climate owners needing prescriptive U <= 0.22 should pass on SR CASE PW Vinyl Fixed Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many SR CASE PW Vinyl Fixed Window glazing packages pass Southern solar-heat rules?

Exactly 3,458 SR CASE PW Vinyl Fixed Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.08 rather than higher 0.51 glass.

Does SR CASE PW Vinyl Fixed Window carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 2,612 of 5,254 SR CASE PW Vinyl Fixed Window glazing builds earn Most Efficient recognition (49.7%), while other variants sit on the standard Version 7.0 tier.

How do the 25C sunset and pre-1978 Lead RRP rules affect SR CASE PW Vinyl Fixed Window?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 SR CASE PW Vinyl Fixed Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on SR CASE PW Vinyl Fixed Window?

Match the NFRC thermal sticker for code MEI and line MEI-A-234 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC SR CASE PW Vinyl Fixed Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)