Skip to main content
Window · Vinyl Frame NFRC MEI · Product Line MEI-A-130 ENERGY STAR Most Efficient Eligible

MI Windows and Doors, LLC — 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window · Picture Window

MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.15 across 11,774 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #136 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.07 to 0.51.

Min U-Factor
0.15
SHGC Range
0.07-0.51
Certified Options
11,774
Category Standing
#136 of 1,352

How does MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window compare thermally against Window peers?

MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window spans 11,774 NFRC test records (MEI), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at -0.04 against the Vinyl median (0.19).

Mapping NFRC SHGC values (0.07 to 0.51) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 2,037 configurations meet ENERGY STAR Most Efficient criteria while 2,723 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors MEI to 2024-02-29 certification (FENSTAR issued 2018-09-11). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 90.0 BTU/hr conductive loss (-31.8% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 11,774 certified glazing combinations for 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 2,723 packages (697 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 5,892 packages (1,057 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 7,221 packages (725 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 8,856 packages (1,555 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does MI Windows and Doors, LLC produce?

Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window appear below.

What thermal performance numbers separate MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window from peers?

Built with Vinyl framing in Fixed Window (FIXD) style, MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window offers 11,774 Version 7.0 configurations from U 0.15 up to 0.32, posting -0.05 against the Window median of 0.20 with 2,037 Most Efficient picks.

Can homeowners install 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window in cold Northern ENERGY STAR counties?

MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window supplies 2,723 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

How do you calculate winter heat conduction for MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window at U 0.15 conducts 90.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Does 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 8,856 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.07 rather than higher 0.51 glass.

Are all 11,774 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window configurations ENERGY STAR Most Efficient?

Not every package qualifies: 2,037 of 11,774 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window glazing builds earn Most Efficient recognition (17.3%), while other variants sit on the standard Version 7.0 tier.

Can homeowners claim Form 5695 credits on MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window in 2026?

Any 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

What permanent glass etch marks verify 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MEI and product line MEI-A-130, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros