Skip to main content
Window · Vinyl Frame NFRC JEL · Product Line JEL-A-900 ENERGY STAR Most Efficient Eligible

JELD-WEN, inc. — Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set · Picture Window

JELD-WEN, inc. engineered the Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set Picture Window line for Northern, North-Central, South-Central, Southern, certifying 13,014 glass-spacer combinations from 0.15 to 0.32 U-Factor and 0.13 to 0.54 SHGC. Relative to other Vinyl models tracked under NFRC JEL, its minimum U-Factor is 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.15
SHGC Range
0.13-0.54
Certified Options
13,014
Category Standing
#136 of 1,352

How does JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set compare thermally against Window peers?

JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct SetHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set at rank #136 of 1,352 (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.13-0.54 band.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 547 configurations meet ENERGY STAR Most Efficient criteria while 2,164 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-02-14 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 90.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 13,014 certified glazing combinations for Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 2,164 packages (132 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 2,461 packages (172 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 6,254 packages (96 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 10,702 packages (463 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set appear below.

Where does JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set stand thermally among ENERGY STAR Window lines?

Across 13,014 tested NFRC glazing configurations, JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set with Vinyl framing and Fixed Window (FIXD) style reaches a 0.15 minimum U-Factor and 0.13-0.54 SHGC band. It places #136 among 1,352 Window series—top 18.4%.

How does JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set satisfy Version 7.0 Northern criteria?

JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set supplies 2,164 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

How does a 3x5 ft Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.15 U-Factor yields 90.0 BTU/hr conductive transfer (-31.8% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set in Southern or South-Central zones?

Yes. 10,702 Southern-certified options inside JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.54 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set holds Most Efficient recognition?

No. Exactly 547 of 13,014 configurations (4.2%) earn ENERGY STAR Most Efficient status in Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set; the remaining standard v7.0 options pass base zone limits only.

How do the 25C sunset and pre-1978 Lead RRP rules affect Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set?

Any Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set units match permits?

Verify NFRC ID JEL and series JEL-A-900 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Premium Vinyl (V-4500) Tilt Single Hung Fixed Direct Set come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros