Window · Vinyl Frame NFRC MEI · Product Line MEI-A-238 ENERGY STAR Most Efficient Eligible

MI Windows and Doors, LLC — SR CASE Vinyl Casement Window · Casement Windows

EPA ENERGY STAR Version 7.0 certifies 10,611 variants inside MI Windows and Doors, LLC SR CASE Vinyl Casement Window, combining Vinyl frame construction with U-Factors spanning 0.15 to 0.31 and SHGC 0.08 to 0.45. Qualifying for Northern, North-Central, South-Central, Southern, this Casement Windows family places #136 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.15
SHGC Range
0.08-0.45
Certified Options
10,611
Category Standing
#136 of 1,352

How does MI Windows and Doors, LLC SR CASE Vinyl Casement Window compare thermally against Window peers?

MI Windows and Doors, LLC SR CASE Vinyl Casement Window achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. SR CASE Vinyl Casement WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing SR CASE Vinyl Casement Window (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

SR CASE Vinyl Casement Window Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across SR CASE Vinyl Casement Window spans 10,611 NFRC test records (MEI), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at -0.04 against the Vinyl median (0.19).

Climate coverage for MI Windows and Doors, LLC SR CASE Vinyl Casement Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 4,889 configurations meet ENERGY STAR Most Efficient criteria while 3,342 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.15 U-Factor yields 90.0 BTU/hr transfer (-42.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-09-11 licensing and 2025-03-04 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 10,611 certified glazing combinations for SR CASE Vinyl Casement Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 3,342 packages (1,614 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 8,323 packages (3,821 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 8,015 packages (3,282 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 8,712 packages (4,318 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does MI Windows and Doors, LLC produce?

Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC SR CASE Vinyl Casement Window appear below.

How efficient is MI Windows and Doors, LLC SR CASE Vinyl Casement Window compared with peer Window models?

MI Windows and Doors, LLC SR CASE Vinyl Casement Window spans 10,611 certified configurations with U-Factors between 0.15 and 0.31 and SHGC values from 0.08 to 0.45. Ranked #136 of 1,352 Window families, it carries 4,889 Most Efficient options.

Is SR CASE Vinyl Casement Window approved for Northern Zone heating climates?

Cold-climate buyers get 3,342 compliant Northern packages inside SR CASE Vinyl Casement Window, reaching down to U 0.15. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.31 options.

What BTU/hr heat transfer results from SR CASE Vinyl Casement Window's 0.15 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 90.0 BTU/hr on SR CASE Vinyl Casement Window's lowest-U package (0.15), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.31 transfer proportionally more energy.

What are the practical limitations of specifying SR CASE Vinyl Casement Window?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on SR CASE Vinyl Casement Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Can you install MI Windows and Doors, LLC SR CASE Vinyl Casement Window in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 8,712 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside MI Windows and Doors, LLC SR CASE Vinyl Casement Window, while total line SHGC reaches 0.45 in colder packages.

Does SR CASE Vinyl Casement Window carry EPA Most Efficient certification across its lineup?

EPA lists 4,889 Most Efficient options (46.1% share) inside MI Windows and Doors, LLC SR CASE Vinyl Casement Window, out of 10,611 total Version 7.0 entries.

Can homeowners claim Form 5695 credits on MI Windows and Doors, LLC SR CASE Vinyl Casement Window in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current SR CASE Vinyl Casement Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

Where are NFRC and IGCC identification marks located on SR CASE Vinyl Casement Window?

Match the NFRC thermal sticker for code MEI and line MEI-A-238 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC SR CASE Vinyl Casement Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)