MI Windows and Doors, LLC — 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window · Picture Window
EPA ENERGY STAR Version 7.0 certifies 8,307 variants inside MI Windows and Doors, LLC 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window, combining Vinyl frame construction with U-Factors spanning 0.12 to 0.32 and SHGC 0.08 to 0.53. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #19 of 1,352 among 1,352 Window families and posts 0.07 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.
- Min U-Factor
- 0.12
- SHGC Range
- 0.08-0.53
- Certified Options
- 8,307
- Category Standing
- #19 of 1,352
How does MI Windows and Doors, LLC 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window compare thermally against Window peers?
MI Windows and Doors, LLC 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window achieves a 0.12 thermal floor across Window lines, placing #19 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 48 certified MI Windows and Doors, LLC series, this Picture Window offers a 0.20 U-Factor adjustment span between 0.32 entry options and 0.12 top-performing glazing. Category standing is #19/1,352 (tied with 16 others at 0.12, more insulating than 97.4% of Window lines, top 2.6%).
Climate coverage for MI Windows and Doors, LLC 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 2,695 configurations meet ENERGY STAR Most Efficient criteria while 3,096 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2025-12-03 and FENSTAR license 2018-09-11 inside EPA Version 7.0 tables. Heat transfer computes to 72.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 8,307 certified glazing combinations for 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 3,096 packages (818 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 6,433 packages (1,978 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 5,155 packages (1,525 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 5,431 packages (2,176 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.12 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Innotech Windows & Doors Inc. — Defender 88PH+ XI Dual Action | Vinyl | 0.12 | 0.12 | 5,850 |
| Innotech Windows & Doors Inc. — Defender 88PH+ XI Fixed | Vinyl | 0.12 | 0.14 | 5,838 |
| Associated Materials, Inc. — A280/A580/S280/S580/A390 Fixed | Vinyl | 0.12 | 0.07 | 12,249 |
| Euroline Windows Inc. — Energeto Neo 76 Small Picture Window | Vinyl | 0.12 | 0.16 | 1,028 |
| Paradigm Window Solutions — 8361 Fixed Casement | Vinyl | 0.12 | 0.15 | 648 |
What other certified series does MI Windows and Doors, LLC produce?
Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window
U-Factor 0.13–0.32 · 6,920 certified options.
1615T Polyvinyl Chloride (PVC) Transom
U-Factor 0.14–0.31 · 3,234 certified options.
3075/3065 Direct Set Picture Window
U-Factor 0.14–0.32 · 35,308 certified options.
SR CASE PW Vinyl Fixed Window
U-Factor 0.14–0.31 · 5,254 certified options.
1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.15–0.32 · 11,774 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window appear below.
How well does 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window by MI Windows and Doors, LLC insulate relative to Window benchmarks?
Built with Vinyl framing in Fixed Window (FIXD) style, MI Windows and Doors, LLC 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window offers 8,307 Version 7.0 configurations from U 0.12 up to 0.32, posting -0.08 against the Window median of 0.20 with 2,695 Most Efficient picks.
Is 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window approved for Northern Zone heating climates?
Cold-climate buyers get 3,096 compliant Northern packages inside 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window, reaching down to U 0.12. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.
How do you calculate winter heat conduction for MI Windows and Doors, LLC 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window at U 0.12 conducts 72.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
Who should NOT choose MI Windows and Doors, LLC 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window for a residential project?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.
How many 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window glazing packages pass Southern solar-heat rules?
Exactly 5,431 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.08 rather than higher 0.53 glass.
Which package tier in 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window holds Most Efficient recognition?
No. Exactly 2,695 of 8,307 configurations (32.4%) earn ENERGY STAR Most Efficient status in 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window; the remaining standard v7.0 options pass base zone limits only.
Do 2026 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window installations qualify for IRS Section 25C tax credits?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How can homeowners confirm delivered MI Windows and Doors, LLC 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window units match permits?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code MEI and product line MEI-A-181, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)