Skip to main content
Window · Vinyl Frame NFRC INN · Product Line INN-M-31 ENERGY STAR Most Efficient Eligible

Innotech Windows & Doors Inc. — Defender 88PH+ XI Fixed · Picture Window

Across 3 Innotech Windows & Doors Inc. certified families, Defender 88PH+ XI Fixed supplies 5,838 Picture Window configurations starting at 0.12 U-Factor and 0.14 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.26 U-Factor and 0.46 SHGC. Its thermal floor ranks #19 of 1,352 category entries—0.08 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.12
SHGC Range
0.14-0.46
Certified Options
5,838
Category Standing
#19 of 1,352

How does Innotech Windows & Doors Inc. Defender 88PH+ XI Fixed compare thermally against Window peers?

Innotech Windows & Doors Inc. Defender 88PH+ XI Fixed achieves a 0.12 thermal floor across Window lines, placing #19 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Defender 88PH+ XI FixedHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Defender 88PH+ XI Fixed (U 0.12).249<=0.15This model: U 0.123140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Defender 88PH+ XI Fixed Cohort StandingMin U-Factor 0.12 stands at rank #19 of 1,352, outperforming 97.4% of peers.Min U-Factor 0.12Rank #19 of 1,352 (97.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Innotech Windows & Doors Inc. Defender 88PH+ XI Fixed standing at #19 of 1,352 certified Window product series, tied with 16 others at 0.12, more insulating than 97.4% of Window lines, top 2.6%. Comparing Vinyl profiles alone (median 0.19) shows -0.07 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 5,760 configurations meet ENERGY STAR Most Efficient criteria while 4,114 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2023-09-25 and FENSTAR license 2023-02-06 inside EPA Version 7.0 tables. Heat transfer computes to 72.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 5,838 certified glazing combinations for Defender 88PH+ XI Fixed (NFRC INN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 4,114 packages (2,896 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 5,762 packages (5,730 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 3,934 packages (3,934 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 3,934 packages (3,934 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.12 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Innotech Windows & Doors Inc. produce?

Compare other active Innotech Windows & Doors Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Innotech Windows & Doors Inc. Defender 88PH+ XI Fixed appear below.

How well does Defender 88PH+ XI Fixed by Innotech Windows & Doors Inc. insulate relative to Window benchmarks?

Across 5,838 tested NFRC glazing configurations, Innotech Windows & Doors Inc. Defender 88PH+ XI Fixed with Vinyl framing and Fixed Window (FIXD) style reaches a 0.12 minimum U-Factor and 0.14-0.46 SHGC band. It places #19 among 1,352 Window series—top 2.6%.

Can homeowners install Defender 88PH+ XI Fixed in cold Northern ENERGY STAR counties?

Innotech Windows & Doors Inc. Defender 88PH+ XI Fixed supplies 4,114 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.26, so inspect the NFRC order sheet before purchase.

What BTU/hr heat transfer results from Defender 88PH+ XI Fixed's 0.12 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.12 U-Factor yields 72.0 BTU/hr conductive transfer (-45.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Innotech Windows & Doors Inc. Defender 88PH+ XI Fixed?

Do not specify Defender 88PH+ XI Fixed without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Defender 88PH+ XI Fixed options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Can you install Innotech Windows & Doors Inc. Defender 88PH+ XI Fixed in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 3,934 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Innotech Windows & Doors Inc. Defender 88PH+ XI Fixed, while total line SHGC reaches 0.46 in colder packages.

Does Defender 88PH+ XI Fixed carry EPA Most Efficient certification across its lineup?

No. Exactly 5,760 of 5,838 configurations (98.7%) earn ENERGY STAR Most Efficient status in Defender 88PH+ XI Fixed; the remaining standard v7.0 options pass base zone limits only.

Do 2026 Defender 88PH+ XI Fixed installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Defender 88PH+ XI Fixed installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do building inspectors verify Defender 88PH+ XI Fixed glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code INN and product line INN-M-31, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Innotech Windows & Doors Inc. Defender 88PH+ XI Fixed come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros