Window · Vinyl Frame NFRC ALP · Product Line ALP-M-17 ENERGY STAR Most Efficient Eligible

Alpen HPP, LLC dba Alpen High Performance Products — Tyrol Tilt Turn · Dual Action (Tilt Turn)

Across 11 Alpen HPP, LLC dba Alpen High Performance Products certified families, Tyrol Tilt Turn supplies 120 Dual Action, Tilt Turn configurations starting at 0.12 U-Factor and 0.15 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.26 U-Factor and 0.43 SHGC. Its thermal floor ranks #19 of 1,352 category entries—0.08 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.12
SHGC Range
0.15-0.43
Certified Options
120
Category Standing
#19 of 1,352

How does Alpen HPP, LLC dba Alpen High Performance Products Tyrol Tilt Turn compare thermally against Window peers?

Alpen HPP, LLC dba Alpen High Performance Products Tyrol Tilt Turn achieves a 0.12 thermal floor across Window lines, placing #19 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Tyrol Tilt TurnHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Tyrol Tilt Turn (U 0.12).249<=0.15This model: U 0.123140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Tyrol Tilt Turn Cohort StandingMin U-Factor 0.12 stands at rank #19 of 1,352, outperforming 97.4% of peers.Min U-Factor 0.12Rank #19 of 1,352 (97.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), Tyrol Tilt Turn reaches 0.12 on its lowest-conductivity package — #8 of 1,009 in Vinyl, tied with 8 others at 0.12, more insulating than 98.4% of Vinyl lines, top 1.6% (-0.07 vs Vinyl peers). Pairing NFRC ID ALP across multi-pane fills shifts U-Factor from 0.26 down toward 0.12.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 113 configurations meet ENERGY STAR Most Efficient criteria while 99 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2023-08-28 and v7.0 data certification on 2025-01-23. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.12 conducts 72.0 BTU/hr (-60.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 120 certified glazing combinations for Tyrol Tilt Turn (NFRC ALP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 99 packages (70 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 117 packages (112 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 59 packages (57 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 59 packages (57 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.12 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Alpen HPP, LLC dba Alpen High Performance Products produce?

Compare other active Alpen HPP, LLC dba Alpen High Performance Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Alpen HPP, LLC dba Alpen High Performance Products Tyrol Tilt Turn appear below.

What U-Factor and SHGC range does Alpen HPP, LLC dba Alpen High Performance Products Tyrol Tilt Turn achieve?

Across 120 tested NFRC glazing configurations, Alpen HPP, LLC dba Alpen High Performance Products Tyrol Tilt Turn with Vinyl framing and Tilt-Turn Dual Action (DATT) style reaches a 0.12 minimum U-Factor and 0.15-0.43 SHGC band. It places #19 among 1,352 Window series—top 2.6%.

Which glazing options in Alpen HPP, LLC dba Alpen High Performance Products Tyrol Tilt Turn meet Northern climate limits?

Yes, 99 packages satisfy Northern ENERGY STAR Version 7.0 rules in Tyrol Tilt Turn. Pairing multi-pane insulation down to 0.12 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What BTU/hr heat transfer results from Tyrol Tilt Turn's 0.12 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Tyrol Tilt Turn at U 0.12 conducts 72.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Alpen HPP, LLC dba Alpen High Performance Products Tyrol Tilt Turn and compare alternatives?

Do not specify Tyrol Tilt Turn without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Tyrol Tilt Turn options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does Tyrol Tilt Turn meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 59 Southern-certified options inside Alpen HPP, LLC dba Alpen High Performance Products Tyrol Tilt Turn satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.43 SHGC on west-facing glass to avoid excess afternoon solar gain.

Does Tyrol Tilt Turn carry EPA Most Efficient certification across its lineup?

Only 113 options out of 120 (94.2%) meet tighter Most Efficient U-Factor and SHGC thresholds in Alpen HPP, LLC dba Alpen High Performance Products Tyrol Tilt Turn, usually requiring triple-pane or upgraded Low-E coatings.

What 2026 federal tax credit and Lead RRP rules apply to Tyrol Tilt Turn?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on Tyrol Tilt Turn?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code ALP and product line ALP-M-17, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Alpen HPP, LLC dba Alpen High Performance Products Tyrol Tilt Turn come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros