Skip to main content
Window · Vinyl Frame NFRC ALP · Product Line ALP-M-31 ENERGY STAR Most Efficient Eligible

Alpen HPP, LLC dba Alpen High Performance Products — Edge Fixed · Picture Window

Across 11 Alpen HPP, LLC dba Alpen High Performance Products certified families, Edge Fixed supplies 166 Picture Window configurations starting at 0.10 U-Factor and 0.17 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.26 U-Factor and 0.50 SHGC. Its thermal floor ranks #6 of 1,352 category entries—0.10 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.10
SHGC Range
0.17-0.50
Certified Options
166
Category Standing
#6 of 1,352

How does Alpen HPP, LLC dba Alpen High Performance Products Edge Fixed compare thermally against Window peers?

Alpen HPP, LLC dba Alpen High Performance Products Edge Fixed achieves a 0.10 thermal floor across Window lines, placing #6 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Edge FixedHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Edge Fixed (U 0.10).249<=0.15This model: U 0.103140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Edge Fixed Cohort StandingMin U-Factor 0.10 stands at rank #6 of 1,352, outperforming 98.0% of peers.Min U-Factor 0.10Rank #6 of 1,352 (98.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), Edge Fixed reaches 0.10 on its lowest-conductivity package — #2 of 1,009 in Vinyl, tied with 2 others at 0.10, more insulating than 99.6% of Vinyl lines, top 0.4% (-0.09 vs Vinyl peers). Pairing NFRC ID ALP across multi-pane fills shifts U-Factor from 0.26 down toward 0.10.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 158 configurations meet ENERGY STAR Most Efficient criteria while 160 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors ALP to 2026-10-09 certification (FENSTAR issued 2023-08-28). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 60.0 BTU/hr conductive loss (-54.5% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 166 certified glazing combinations for Edge Fixed (NFRC ALP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 160 packages (126 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 132 packages (126 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 56 packages (52 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 56 packages (52 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.10 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Alpen HPP, LLC dba Alpen High Performance Products produce?

Compare other active Alpen HPP, LLC dba Alpen High Performance Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Alpen HPP, LLC dba Alpen High Performance Products Edge Fixed appear below.

What U-Factor and SHGC range does Alpen HPP, LLC dba Alpen High Performance Products Edge Fixed achieve?

Built with Vinyl framing in Fixed Window (FIXD) style, Alpen HPP, LLC dba Alpen High Performance Products Edge Fixed offers 166 Version 7.0 configurations from U 0.10 up to 0.26, posting -0.10 against the Window median of 0.20 with 158 Most Efficient picks.

Does Alpen HPP, LLC dba Alpen High Performance Products Edge Fixed qualify for the ENERGY STAR Northern Zone?

Yes, 160 packages satisfy Northern ENERGY STAR Version 7.0 rules in Edge Fixed. Pairing multi-pane insulation down to 0.10 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How much winter heat loss does Edge Fixed conduct across a 15 sq ft opening?

At U 0.10, a standard 3x5 ft (15 sq ft) Edge Fixed opening transfers 60.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -72.0 BTU/hr difference.

When should a buyer skip Alpen HPP, LLC dba Alpen High Performance Products Edge Fixed and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Edge Fixed options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Does Edge Fixed meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, Edge Fixed holds 56 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.17 SHGC in cooling climates.

Does Edge Fixed carry EPA Most Efficient certification across its lineup?

EPA lists 158 Most Efficient options (95.2% share) inside Alpen HPP, LLC dba Alpen High Performance Products Edge Fixed, out of 166 total Version 7.0 entries.

Can homeowners claim Form 5695 credits on Alpen HPP, LLC dba Alpen High Performance Products Edge Fixed in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on Edge Fixed?

Inspectors match the temporary NFRC sticker (U 0.10-0.26, SHGC 0.17-0.50) against permit drawings for line ALP-M-31. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Alpen HPP, LLC dba Alpen High Performance Products Edge Fixed come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros