Skip to main content
Window · Vinyl Frame NFRC SBP · Product Line SBP-A-52 ENERGY STAR Most Efficient Eligible

Simonton Building Products, Inc. - Simonton Windows — 325-325 CA · Casement Windows

Positioning #362/1,352 in certified Window, Simonton Building Products, Inc. - Simonton Windows 325-325 CA pairs Vinyl frame construction with 13,628 glazing options rated between 0.09 and 0.46 SHGC across Northern, North-Central, South-Central, Southern. Across 14 certified Simonton Building Products, Inc. - Simonton Windows product families, its thermal resistance spans 0.17 to 0.32 U-Factor and the line includes 1,473 ENERGY STAR Most Efficient packages (10.8% of line).

Min U-Factor
0.17
SHGC Range
0.09-0.46
Certified Options
13,628
Category Standing
#362 of 1,352

How does Simonton Building Products, Inc. - Simonton Windows 325-325 CA compare thermally against Window peers?

Simonton Building Products, Inc. - Simonton Windows 325-325 CA achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 325-325 CAHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 325-325 CA (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

325-325 CA Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Simonton Building Products, Inc. - Simonton Windows 325-325 CA at rank #362 of 1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.09-0.46 band.

Mapping NFRC SHGC values (0.09 to 0.46) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 1,473 configurations meet ENERGY STAR Most Efficient criteria while 1,656 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors SBP to 2024-02-21 certification (FENSTAR issued 2018-08-23). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 102.0 BTU/hr conductive loss (-22.7% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 13,628 certified glazing combinations for 325-325 CA (NFRC SBP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 1,656 packages (98 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 7,113 packages (278 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 9,326 packages (242 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 11,630 packages (1,437 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Quaker Window Products — V300 Casement Vinyl 0.17 0.09 11,114
Quaker Window Products — V300 Awning Vinyl 0.17 0.09 11,097
PGT Industries — AW5440/5540 Vinyl 0.17 0.08 16,848
MI Windows and Doors, LLC — 1555-1556 Polyvinyl Chloride (PVC) Double Hung Window Vinyl 0.17 0.06 17,618
PGT Industries — CA5440/5540 Vinyl 0.17 0.08 17,693

What other certified series does Simonton Building Products, Inc. - Simonton Windows produce?

Compare other active Simonton Building Products, Inc. - Simonton Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Simonton Building Products, Inc. - Simonton Windows 325-325 CA appear below.

What U-Factor and SHGC range does Simonton Building Products, Inc. - Simonton Windows 325-325 CA achieve?

Simonton Building Products, Inc. - Simonton Windows 325-325 CA spans 13,628 certified configurations with U-Factors between 0.17 and 0.32 and SHGC values from 0.09 to 0.46. Ranked #362 of 1,352 Window families, it carries 1,473 Most Efficient options.

Is 325-325 CA approved for Northern Zone heating climates?

Yes, 1,656 packages satisfy Northern ENERGY STAR Version 7.0 rules in 325-325 CA. Pairing multi-pane insulation down to 0.17 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How do you calculate winter heat conduction for Simonton Building Products, Inc. - Simonton Windows 325-325 CA?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 102.0 BTU/hr on 325-325 CA's lowest-U package (0.17), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

What are the practical limitations of specifying 325-325 CA?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 325-325 CA options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Does 325-325 CA meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 11,630 Southern-approved options within 325-325 CA spanning SHGC down to 0.09. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Are all 13,628 325-325 CA configurations ENERGY STAR Most Efficient?

No. Exactly 1,473 of 13,628 configurations (10.8%) earn ENERGY STAR Most Efficient status in 325-325 CA; the remaining standard v7.0 options pass base zone limits only.

Do 2026 325-325 CA installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Simonton Building Products, Inc. - Simonton Windows upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify 325-325 CA glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code SBP and product line SBP-A-52, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Simonton Building Products, Inc. - Simonton Windows 325-325 CA come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros