Window · Vinyl Frame NFRC SBP · Product Line SBP-A-54 ENERGY STAR Most Efficient Eligible

Simonton Building Products, Inc. - Simonton Windows — 325-325 CA PW (No Hinge) · Picture Window

EPA ENERGY STAR Version 7.0 certifies 19,435 variants inside Simonton Building Products, Inc. - Simonton Windows 325-325 CA PW (No Hinge), combining Vinyl frame construction with U-Factors spanning 0.15 to 0.32 and SHGC 0.08 to 0.54. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #136 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.15
SHGC Range
0.08-0.54
Certified Options
19,435
Category Standing
#136 of 1,352

How does Simonton Building Products, Inc. - Simonton Windows 325-325 CA PW (No Hinge) compare thermally against Window peers?

Simonton Building Products, Inc. - Simonton Windows 325-325 CA PW (No Hinge) achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 325-325 CA PW (No Hinge)Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 325-325 CA PW (No Hinge) (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

325-325 CA PW (No Hinge) Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 325-325 CA PW (No Hinge) spans 19,435 NFRC test records (SBP), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at -0.04 against the Vinyl median (0.19).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 3,345 configurations meet ENERGY STAR Most Efficient criteria while 5,061 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors SBP to 2024-02-21 certification (FENSTAR issued 2018-08-23). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 90.0 BTU/hr conductive loss (-31.8% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 19,435 certified glazing combinations for 325-325 CA PW (No Hinge) (NFRC SBP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 5,061 packages (704 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 11,803 packages (1,220 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 10,431 packages (808 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 13,286 packages (2,881 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Milgard Manufacturing, Inc. — 8354 Fixed Vinyl 0.15 0.09 16,371
Wincore Window Company, LLC — 5400, 7700 Casement Picture Window Vinyl 0.15 0.07 16,031
Milgard Manufacturing, Inc. — 8420T2.8430T2.8470T2 Awning Vinyl 0.15 0.08 23,678
Milgard Manufacturing, Inc. — 8520T2.8530T2.8570T2 Casement Vinyl 0.15 0.08 24,195
PGT Industries — PW5440/5540 Vinyl 0.15 0.07 25,346

What other certified series does Simonton Building Products, Inc. - Simonton Windows produce?

Compare other active Simonton Building Products, Inc. - Simonton Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Simonton Building Products, Inc. - Simonton Windows 325-325 CA PW (No Hinge) appear below.

How well does 325-325 CA PW (No Hinge) by Simonton Building Products, Inc. - Simonton Windows insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 19,435 configurations for Simonton Building Products, Inc. - Simonton Windows 325-325 CA PW (No Hinge) covering Northern, North-Central, South-Central, Southern, dropping down to U 0.15 versus a 0.20 Window median. Only 3,345 options earn Most Efficient status.

Is 325-325 CA PW (No Hinge) approved for Northern Zone heating climates?

Yes, 5,061 packages satisfy Northern ENERGY STAR Version 7.0 rules in 325-325 CA PW (No Hinge). Pairing multi-pane insulation down to 0.15 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How much winter heat loss does 325-325 CA PW (No Hinge) conduct across a 15 sq ft opening?

Using NFRC SBP U-Factor 0.15, a 15 sq ft Fixed Window (FIXD) assembly conducts 90.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-42.0 BTU/hr margin).

Who should NOT choose Simonton Building Products, Inc. - Simonton Windows 325-325 CA PW (No Hinge) for a residential project?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 325-325 CA PW (No Hinge) options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Is 325-325 CA PW (No Hinge) suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 13,286 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Simonton Building Products, Inc. - Simonton Windows 325-325 CA PW (No Hinge), while total line SHGC reaches 0.54 in colder packages.

How many Simonton Building Products, Inc. - Simonton Windows 325-325 CA PW (No Hinge) variants earn ENERGY STAR Most Efficient?

EPA lists 3,345 Most Efficient options (17.2% share) inside Simonton Building Products, Inc. - Simonton Windows 325-325 CA PW (No Hinge), out of 19,435 total Version 7.0 entries.

Do 2026 325-325 CA PW (No Hinge) installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 325-325 CA PW (No Hinge) installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on 325-325 CA PW (No Hinge)?

Confirm both the paper NFRC label and permanent corner glass etch match line SBP-A-54 and NFRC ID SBP before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Simonton Building Products, Inc. - Simonton Windows 325-325 CA PW (No Hinge) come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros