Skip to main content
Window · Vinyl Frame NFRC PGT · Product Line PGT-A-233 ENERGY STAR Most Efficient Eligible

PGT Industries — PW5440/5540 · Picture Window

Positioning #136/1,352 in certified Window, PGT Industries PW5440/5540 pairs Vinyl frame construction with 25,346 glazing options rated between 0.07 and 0.44 SHGC across Northern, North-Central, South-Central, Southern. Across 8 certified PGT Industries product families, its thermal resistance spans 0.15 to 0.32 U-Factor and the line includes 279 ENERGY STAR Most Efficient packages (1.1% of line).

Min U-Factor
0.15
SHGC Range
0.07-0.44
Certified Options
25,346
Category Standing
#136 of 1,352

How does PGT Industries PW5440/5540 compare thermally against Window peers?

PGT Industries PW5440/5540 achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. PW5440/5540Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing PW5440/5540 (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

PW5440/5540 Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), PW5440/5540 reaches 0.15 on its lowest-conductivity package — #89 of 1,009 in Vinyl, tied with 80 others at 0.15, more insulating than 83.3% of Vinyl lines, top 16.7% (-0.04 vs Vinyl peers). Pairing NFRC ID PGT across multi-pane fills shifts U-Factor from 0.32 down toward 0.15.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 279 configurations meet ENERGY STAR Most Efficient criteria while 372 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 90.0 BTU/hr (-31.8% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2025-09-29.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 25,346 certified glazing combinations for PW5440/5540 (NFRC PGT) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 372 packages (63 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 6,627 packages (137 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 12,783 packages (90 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 23,711 packages (225 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does PGT Industries produce?

Compare other active PGT Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to PGT Industries PW5440/5540 appear below.

What U-Factor and SHGC range does PGT Industries PW5440/5540 achieve?

Built with Vinyl framing in Fixed Window (FIXD) style, PGT Industries PW5440/5540 offers 25,346 Version 7.0 configurations from U 0.15 up to 0.32, posting -0.05 against the Window median of 0.20 with 279 Most Efficient picks.

Is PW5440/5540 approved for Northern Zone heating climates?

Cold-climate buyers get 372 compliant Northern packages inside PW5440/5540, reaching down to U 0.15. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What conductive BTU/hr difference separates PW5440/5540 from the 0.22 Northern rule?

Using NFRC PGT U-Factor 0.15, a 15 sq ft Fixed Window (FIXD) assembly conducts 90.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-42.0 BTU/hr margin).

Who should NOT choose PGT Industries PW5440/5540 for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on PW5440/5540 options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Does PW5440/5540 meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 23,711 Southern-approved options within PW5440/5540 spanning SHGC down to 0.07. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does PW5440/5540 carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 279 of 25,346 PW5440/5540 glazing builds earn Most Efficient recognition (1.1%), while other variants sit on the standard Version 7.0 tier.

What 2026 federal tax credit and Lead RRP rules apply to PW5440/5540?

Any PW5440/5540 purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do building inspectors verify PW5440/5540 glass specs on job sites?

Verify NFRC ID PGT and series PGT-A-233 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for PGT Industries PW5440/5540 come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros