Window · Vinyl Frame NFRC PGT · Product Line PGT-A-230 ENERGY STAR Most Efficient Eligible

PGT Industries — DH5460/5560 · Double Hung

Across 8 PGT Industries certified families, DH5460/5560 supplies 6,757 Double Hung configurations starting at 0.18 U-Factor and 0.08 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.42 SHGC. Its thermal floor ranks #477 of 1,352 category entries—0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.18
SHGC Range
0.08-0.42
Certified Options
6,757
Category Standing
#477 of 1,352

How does PGT Industries DH5460/5560 compare thermally against Window peers?

PGT Industries DH5460/5560 achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. DH5460/5560Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing DH5460/5560 (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

DH5460/5560 Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows PGT Industries DH5460/5560 standing at #477 of 1,352 certified Window product series, tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%. Comparing Vinyl profiles alone (median 0.19) shows -0.01 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.08 to 0.42) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 84 configurations meet ENERGY STAR Most Efficient criteria while 64 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.18 U-Factor yields 108.0 BTU/hr transfer (-24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2025-07-31 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 6,757 certified glazing combinations for DH5460/5560 (NFRC PGT) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 64 packages (32 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 160 packages (68 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 481 packages (52 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 6,706 packages (64 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does PGT Industries produce?

Compare other active PGT Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to PGT Industries DH5460/5560 appear below.

What thermal performance numbers separate PGT Industries DH5460/5560 from peers?

Across 6,757 tested NFRC glazing configurations, PGT Industries DH5460/5560 with Vinyl framing and Double-Hung (VSDH) style reaches a 0.18 minimum U-Factor and 0.08-0.42 SHGC band. It places #477 among 1,352 Window series—top 41.6%.

Does PGT Industries DH5460/5560 qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 64 compliant Northern packages inside DH5460/5560, reaching down to U 0.18. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What BTU/hr heat transfer results from DH5460/5560's 0.18 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.18 U-Factor yields 108.0 BTU/hr conductive transfer (-18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for PGT Industries DH5460/5560?

Cold-climate owners needing prescriptive U <= 0.22 should pass on DH5460/5560 options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many DH5460/5560 glazing packages pass Southern solar-heat rules?

Exactly 6,706 DH5460/5560 options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.08 rather than higher 0.42 glass.

How many PGT Industries DH5460/5560 variants earn ENERGY STAR Most Efficient?

No. Exactly 84 of 6,757 configurations (1.2%) earn ENERGY STAR Most Efficient status in DH5460/5560; the remaining standard v7.0 options pass base zone limits only.

Do 2026 DH5460/5560 installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on DH5460/5560?

Inspectors match the temporary NFRC sticker (U 0.18-0.32, SHGC 0.08-0.42) against permit drawings for line PGT-A-230. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for PGT Industries DH5460/5560 come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros