Skip to main content
Window · Vinyl Frame NFRC MIL · Product Line MIL-A-224 ENERGY STAR Most Efficient Eligible

Milgard Manufacturing, Inc. — 8120/8130/8170 Horizontal Slider · Single Slider

Milgard Manufacturing, Inc. 8120/8130/8170 Horizontal Slider is a Single Slider assembly with a Vinyl frame that reaches a minimum U-Factor of 0.18 across 9,007 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #477 of 1,352 in Window, its thermal floor is 0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.09 to 0.48.

Min U-Factor
0.18
SHGC Range
0.09-0.48
Certified Options
9,007
Category Standing
#477 of 1,352

How does Milgard Manufacturing, Inc. 8120/8130/8170 Horizontal Slider compare thermally against Window peers?

Milgard Manufacturing, Inc. 8120/8130/8170 Horizontal Slider achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 8120/8130/8170 Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 8120/8130/8170 Horizontal Slider (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

8120/8130/8170 Horizontal Slider Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 8120/8130/8170 Horizontal Slider reaches 0.18 on its lowest-conductivity package — #354 of 1,009 in Vinyl, tied with 74 others at 0.18, more insulating than 57.6% of Vinyl lines, top 42.4% (-0.01 vs Vinyl peers). Pairing NFRC ID MIL across multi-pane fills shifts U-Factor from 0.32 down toward 0.18.

Regional qualification covers Northern, North-Central, South-Central, Southern. 116 configurations meet ENERGY STAR Most Efficient criteria while 460 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2019-01-08 and v7.0 data certification on 2025-01-30. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.18 conducts 108.0 BTU/hr (-24.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 9,007 certified glazing combinations for 8120/8130/8170 Horizontal Slider (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 460 packages (37 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,608 packages (48 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 4,469 packages (33 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 8,299 packages (99 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
PGT Industries — DH5460/5560 Vinyl 0.18 0.08 6,757
JELD-WEN, inc. — Premium Vinyl (V-4500) Tilt Single Hung Vinyl 0.18 0.12 11,430
Ply Gem Window Group — Pro Series Classic Sidelite/Transom Vinyl 0.18 0.12 5,388
DRUTEX S.A. — IGLO ENERGY Classic Transom Vinyl 0.18 0.03 4,044
Vinylmax LLC — CA55/CA74 Casement Vinyl 0.18 0.13 3,415

What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 8120/8130/8170 Horizontal Slider appear below.

How efficient is Milgard Manufacturing, Inc. 8120/8130/8170 Horizontal Slider compared with peer Window models?

Testing puts Milgard Manufacturing, Inc. 8120/8130/8170 Horizontal Slider at rank #477 of 1,352 Window entries with U 0.18 to 0.32 across 9,007 configurations. Solar heat gain ranges between 0.09 and 0.48 across Northern, North-Central, South-Central, Southern.

Which glazing options in Milgard Manufacturing, Inc. 8120/8130/8170 Horizontal Slider meet Northern climate limits?

Cold-climate buyers get 460 compliant Northern packages inside 8120/8130/8170 Horizontal Slider, reaching down to U 0.18. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What BTU/hr heat transfer results from 8120/8130/8170 Horizontal Slider's 0.18 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 108.0 BTU/hr on 8120/8130/8170 Horizontal Slider's lowest-U package (0.18), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

What are the practical limitations of specifying 8120/8130/8170 Horizontal Slider?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 8120/8130/8170 Horizontal Slider options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Does 8120/8130/8170 Horizontal Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 8,299 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Milgard Manufacturing, Inc. 8120/8130/8170 Horizontal Slider, while total line SHGC reaches 0.48 in colder packages.

Which package tier in 8120/8130/8170 Horizontal Slider holds Most Efficient recognition?

Not every package qualifies: 116 of 9,007 8120/8130/8170 Horizontal Slider glazing builds earn Most Efficient recognition (1.3%), while other variants sit on the standard Version 7.0 tier.

What federal compliance checks govern 2026 8120/8130/8170 Horizontal Slider window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Milgard Manufacturing, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered Milgard Manufacturing, Inc. 8120/8130/8170 Horizontal Slider units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line MIL-A-224 and NFRC ID MIL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 8120/8130/8170 Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)