Window · Vinyl Frame NFRC VIM · Product Line VIM-M-15 ENERGY STAR Most Efficient Eligible

Vinylmax LLC — CA55/CA74 Casement · Casement Windows

Across 12 Vinylmax LLC certified families, CA55/CA74 Casement supplies 3,415 Casement Windows configurations starting at 0.18 U-Factor and 0.13 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.43 SHGC. Its thermal floor ranks #477 of 1,352 category entries—0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.18
SHGC Range
0.13-0.43
Certified Options
3,415
Category Standing
#477 of 1,352

How does Vinylmax LLC CA55/CA74 Casement compare thermally against Window peers?

Vinylmax LLC CA55/CA74 Casement achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. CA55/CA74 CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing CA55/CA74 Casement (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

CA55/CA74 Casement Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 12 certified Vinylmax LLC series, this Casement Windows offers a 0.14 U-Factor adjustment span between 0.32 entry options and 0.18 top-performing glazing. Category standing is #477/1,352 (tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 528 configurations meet ENERGY STAR Most Efficient criteria while 814 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2025-06-03. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.18 conducts 108.0 BTU/hr (-24.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,415 certified glazing combinations for CA55/CA74 Casement (NFRC VIM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 814 packages (90 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 2,058 packages (242 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 2,043 packages (178 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,546 packages (464 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Vinylmax LLC produce?

Compare other active Vinylmax LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vinylmax LLC CA55/CA74 Casement appear below.

What thermal performance numbers separate Vinylmax LLC CA55/CA74 Casement from peers?

Built with Vinyl framing in Casement Single-Vent (CSSV) style, Vinylmax LLC CA55/CA74 Casement offers 3,415 Version 7.0 configurations from U 0.18 up to 0.32, posting -0.02 against the Window median of 0.20 with 528 Most Efficient picks.

Which glazing options in Vinylmax LLC CA55/CA74 Casement meet Northern climate limits?

Yes, 814 packages satisfy Northern ENERGY STAR Version 7.0 rules in CA55/CA74 Casement. Pairing multi-pane insulation down to 0.18 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How much winter heat loss does CA55/CA74 Casement conduct across a 15 sq ft opening?

At U 0.18, a standard 3x5 ft (15 sq ft) CA55/CA74 Casement opening transfers 108.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -24.0 BTU/hr difference.

What homeowner profiles are a poor match for Vinylmax LLC CA55/CA74 Casement?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on CA55/CA74 Casement options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in CA55/CA74 Casement?

Yes, CA55/CA74 Casement holds 2,546 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.13 SHGC in cooling climates.

Does CA55/CA74 Casement carry EPA Most Efficient certification across its lineup?

EPA lists 528 Most Efficient options (15.5% share) inside Vinylmax LLC CA55/CA74 Casement, out of 3,415 total Version 7.0 entries.

How do the 25C sunset and pre-1978 Lead RRP rules affect CA55/CA74 Casement?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 CA55/CA74 Casement installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How can homeowners confirm delivered Vinylmax LLC CA55/CA74 Casement units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code VIM and product line VIM-M-15, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vinylmax LLC CA55/CA74 Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)