Skip to main content
Window · Vinyl Frame NFRC MEI · Product Line MEI-A-224

MI Windows and Doors, LLC — 1615 Polyvinyl Chloride (PVC) Sidelite · Sidelite

MI Windows and Doors, LLC engineered the 1615 Polyvinyl Chloride (PVC) Sidelite Sidelite line for Northern, North-Central, South-Central, Southern, certifying 3,045 glass-spacer combinations from 0.18 to 0.28 U-Factor and 0.06 to 0.40 SHGC. Relative to other Vinyl models tracked under NFRC MEI, its minimum U-Factor is 0.01 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.18
SHGC Range
0.06-0.40
Certified Options
3,045
Category Standing
#477 of 1,352

How does MI Windows and Doors, LLC 1615 Polyvinyl Chloride (PVC) Sidelite compare thermally against Window peers?

MI Windows and Doors, LLC 1615 Polyvinyl Chloride (PVC) Sidelite achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1615 Polyvinyl Chloride (PVC) SideliteHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 1615 Polyvinyl Chloride (PVC) Sidelite (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1615 Polyvinyl Chloride (PVC) Sidelite Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 48 certified MI Windows and Doors, LLC series, this Sidelite offers a 0.10 U-Factor adjustment span between 0.28 entry options and 0.18 top-performing glazing. Category standing is #477/1,352 (tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 2,264 combinations qualify in the Northern Zone alongside 2,670 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Data provenance links certification 2025-03-04 and FENSTAR license 2018-09-11 inside EPA Version 7.0 tables. Heat transfer computes to 108.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,045 certified glazing combinations for 1615 Polyvinyl Chloride (PVC) Sidelite (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 2,264 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 2,264 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 2,670 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 2,670 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Amsco Windows — VZ1 Hampton Awning Vinyl 0.18 0.09 3,114
Amsco Windows — VZ1 Hampton Casement Vinyl 0.18 0.09 3,164
Windsor Windows and Doors — Next Dimension Single Slider Vinyl 0.18 0.12 3,241
Vinylmax LLC — CA55/CA74 Awning Vinyl 0.18 0.13 2,697
Vinylmax LLC — CA55/CA74 Casement Vinyl 0.18 0.13 3,415

What other certified series does MI Windows and Doors, LLC produce?

Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 1615 Polyvinyl Chloride (PVC) Sidelite appear below.

Where does MI Windows and Doors, LLC 1615 Polyvinyl Chloride (PVC) Sidelite stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 3,045 configurations for MI Windows and Doors, LLC 1615 Polyvinyl Chloride (PVC) Sidelite covering Northern, North-Central, South-Central, Southern, dropping down to U 0.18 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Does MI Windows and Doors, LLC 1615 Polyvinyl Chloride (PVC) Sidelite qualify for the ENERGY STAR Northern Zone?

MI Windows and Doors, LLC 1615 Polyvinyl Chloride (PVC) Sidelite supplies 2,264 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.28, so inspect the NFRC order sheet before purchase.

How do you calculate winter heat conduction for MI Windows and Doors, LLC 1615 Polyvinyl Chloride (PVC) Sidelite?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 1615 Polyvinyl Chloride (PVC) Sidelite at U 0.18 conducts 108.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying 1615 Polyvinyl Chloride (PVC) Sidelite?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1615 Polyvinyl Chloride (PVC) Sidelite options exceeding U 0.22. Additionally, do not order Fixed Sidelite (FXSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does 1615 Polyvinyl Chloride (PVC) Sidelite meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 2,670 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside MI Windows and Doors, LLC 1615 Polyvinyl Chloride (PVC) Sidelite, while total line SHGC reaches 0.40 in colder packages.

Does 1615 Polyvinyl Chloride (PVC) Sidelite carry EPA Most Efficient certification across its lineup?

No. Zero of the 3,045 configurations in MI Windows and Doors, LLC 1615 Polyvinyl Chloride (PVC) Sidelite hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What federal compliance checks govern 2026 1615 Polyvinyl Chloride (PVC) Sidelite window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 MI Windows and Doors, LLC upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered MI Windows and Doors, LLC 1615 Polyvinyl Chloride (PVC) Sidelite units match permits?

Inspectors match the temporary NFRC sticker (U 0.18-0.28, SHGC 0.06-0.40) against permit drawings for line MEI-A-224. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 1615 Polyvinyl Chloride (PVC) Sidelite come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros