Window · Vinyl Frame NFRC AMS · Product Line AMS-A-80 ENERGY STAR Most Efficient Eligible

Amsco Windows — VZ1 Hampton Casement · Casement Windows

Amsco Windows VZ1 Hampton Casement is a Casement Windows assembly with a Vinyl frame that reaches a minimum U-Factor of 0.18 across 3,164 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #477 of 1,352 in Window, its thermal floor is 0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.09 to 0.40.

Min U-Factor
0.18
SHGC Range
0.09-0.40
Certified Options
3,164
Category Standing
#477 of 1,352

How does Amsco Windows VZ1 Hampton Casement compare thermally against Window peers?

Amsco Windows VZ1 Hampton Casement achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. VZ1 Hampton CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing VZ1 Hampton Casement (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

VZ1 Hampton Casement Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 12 certified Amsco Windows series, this Casement Windows offers a 0.13 U-Factor adjustment span between 0.31 entry options and 0.18 top-performing glazing. Category standing is #477/1,352 (tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%).

Regional qualification covers Northern, North-Central, South-Central, Southern. 96 configurations meet ENERGY STAR Most Efficient criteria while 112 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2026-09-25 and FENSTAR license 2018-10-08 inside EPA Version 7.0 tables. Heat transfer computes to 108.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,164 certified glazing combinations for VZ1 Hampton Casement (NFRC AMS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 112 packages (14 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,224 packages (52 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 2,194 packages (44 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,969 packages (88 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Amsco Windows produce?

Compare other active Amsco Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Amsco Windows VZ1 Hampton Casement appear below.

How well does VZ1 Hampton Casement by Amsco Windows insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 3,164 configurations for Amsco Windows VZ1 Hampton Casement covering Northern, North-Central, South-Central, Southern, dropping down to U 0.18 versus a 0.20 Window median. Only 96 options earn Most Efficient status.

Which glazing options in Amsco Windows VZ1 Hampton Casement meet Northern climate limits?

Yes, 112 packages satisfy Northern ENERGY STAR Version 7.0 rules in VZ1 Hampton Casement. Pairing multi-pane insulation down to 0.18 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What BTU/hr heat transfer results from VZ1 Hampton Casement's 0.18 minimum U-Factor?

At U 0.18, a standard 3x5 ft (15 sq ft) VZ1 Hampton Casement opening transfers 108.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -24.0 BTU/hr difference.

What homeowner profiles are a poor match for Amsco Windows VZ1 Hampton Casement?

Skip VZ1 Hampton Casement if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on VZ1 Hampton Casement options exceeding U 0.22.

How many VZ1 Hampton Casement glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 2,969 Southern-approved options within VZ1 Hampton Casement spanning SHGC down to 0.09. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Are all 3,164 VZ1 Hampton Casement configurations ENERGY STAR Most Efficient?

EPA lists 96 Most Efficient options (3.0% share) inside Amsco Windows VZ1 Hampton Casement, out of 3,164 total Version 7.0 entries.

What 2026 federal tax credit and Lead RRP rules apply to VZ1 Hampton Casement?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Amsco Windows upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify VZ1 Hampton Casement glass specs on job sites?

Verify NFRC ID AMS and series AMS-A-80 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Amsco Windows VZ1 Hampton Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)