Skip to main content
Window · Vinyl Frame NFRC VIM · Product Line VIM-M-16 ENERGY STAR Most Efficient Eligible

Vinylmax LLC — CA55/CA74 Awning · Awning (Projected)

Positioning #477/1,352 in certified Window, Vinylmax LLC CA55/CA74 Awning pairs Vinyl frame construction with 2,697 glazing options rated between 0.13 and 0.43 SHGC across Northern, North-Central, South-Central, Southern. Across 12 certified Vinylmax LLC product families, its thermal resistance spans 0.18 to 0.32 U-Factor and the line includes 477 ENERGY STAR Most Efficient packages (17.7% of line).

Min U-Factor
0.18
SHGC Range
0.13-0.43
Certified Options
2,697
Category Standing
#477 of 1,352

How does Vinylmax LLC CA55/CA74 Awning compare thermally against Window peers?

Vinylmax LLC CA55/CA74 Awning achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. CA55/CA74 AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing CA55/CA74 Awning (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

CA55/CA74 Awning Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across CA55/CA74 Awning spans 2,697 NFRC test records (VIM), ranking #477 of 1,352 Window families (tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%). Its 0.18 thermal floor compares at -0.01 against the Vinyl median (0.19).

Mapping NFRC SHGC values (0.13 to 0.43) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 477 configurations meet ENERGY STAR Most Efficient criteria while 688 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-03-25 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 108.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,697 certified glazing combinations for CA55/CA74 Awning (NFRC VIM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 688 packages (75 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,712 packages (221 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,638 packages (170 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,980 packages (426 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Vinylmax LLC produce?

Compare other active Vinylmax LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vinylmax LLC CA55/CA74 Awning appear below.

Where does Vinylmax LLC CA55/CA74 Awning stand thermally among ENERGY STAR Window lines?

Vinylmax LLC CA55/CA74 Awning spans 2,697 certified configurations with U-Factors between 0.18 and 0.32 and SHGC values from 0.13 to 0.43. Ranked #477 of 1,352 Window families, it carries 477 Most Efficient options.

Does Vinylmax LLC CA55/CA74 Awning qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 688 CA55/CA74 Awning packages (U floor 0.18, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

How much winter heat loss does CA55/CA74 Awning conduct across a 15 sq ft opening?

Using NFRC VIM U-Factor 0.18, a 15 sq ft Projected Awning (PRAW) assembly conducts 108.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-24.0 BTU/hr margin).

What homeowner profiles are a poor match for Vinylmax LLC CA55/CA74 Awning?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on CA55/CA74 Awning options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Does CA55/CA74 Awning meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, CA55/CA74 Awning holds 1,980 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.13 SHGC in cooling climates.

How many Vinylmax LLC CA55/CA74 Awning variants earn ENERGY STAR Most Efficient?

EPA lists 477 Most Efficient options (17.7% share) inside Vinylmax LLC CA55/CA74 Awning, out of 2,697 total Version 7.0 entries.

What 2026 federal tax credit and Lead RRP rules apply to CA55/CA74 Awning?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Vinylmax LLC upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered Vinylmax LLC CA55/CA74 Awning units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code VIM and product line VIM-M-16, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vinylmax LLC CA55/CA74 Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros