Vinylmax LLC — A4 Single Hung · Single Hung
Across 12 Vinylmax LLC certified families, A4 Single Hung supplies 3,907 Single Hung configurations starting at 0.16 U-Factor and 0.11 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.50 SHGC. Its thermal floor ranks #250 of 1,352 category entries—0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.16
- SHGC Range
- 0.11-0.50
- Certified Options
- 3,907
- Category Standing
- #250 of 1,352
How does Vinylmax LLC A4 Single Hung compare thermally against Window peers?
Vinylmax LLC A4 Single Hung achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Vinyl cohort (0.19 median U-Factor), A4 Single Hung reaches 0.16 on its lowest-conductivity package — #170 of 1,009 in Vinyl, tied with 100 others at 0.16, more insulating than 73.2% of Vinyl lines, top 26.8% (-0.03 vs Vinyl peers). Pairing NFRC ID VIM across multi-pane fills shifts U-Factor from 0.32 down toward 0.16.
Climate coverage for Vinylmax LLC A4 Single Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 565 configurations meet ENERGY STAR Most Efficient criteria while 1,367 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 96.0 BTU/hr (-27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2023-12-21.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 3,907 certified glazing combinations for A4 Single Hung (NFRC VIM) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 1,367 packages (237 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 1,977 packages (414 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 1,718 packages (294 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 2,361 packages (399 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| DRUTEX S.A. — IGLO ENERGY Classic Casement | Vinyl | 0.16 | 0.03 | 4,020 |
| DRUTEX S.A. — IGLO ENERGY Classic Tilt Turn | Vinyl | 0.16 | 0.04 | 3,652 |
| MI Windows and Doors, LLC — 1653 Polyvinyl Chloride (PVC) Double Hung Window | Vinyl | 0.16 | 0.06 | 4,599 |
| Paradigm Window Solutions — 8351 Casement | Vinyl | 0.16 | 0.12 | 2,533 |
| Seaway Manufacturing Corporation — Lighthouse/Commander/Epiphany Casement | Vinyl | 0.16 | 0.09 | 2,523 |
What other certified series does Vinylmax LLC produce?
Compare other active Vinylmax LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vinylmax LLC A4 Single Hung appear below.
What U-Factor and SHGC range does Vinylmax LLC A4 Single Hung achieve?
Vinylmax LLC A4 Single Hung spans 3,907 certified configurations with U-Factors between 0.16 and 0.32 and SHGC values from 0.11 to 0.50. Ranked #250 of 1,352 Window families, it carries 565 Most Efficient options.
Which glazing options in Vinylmax LLC A4 Single Hung meet Northern climate limits?
Yes, 1,367 packages satisfy Northern ENERGY STAR Version 7.0 rules in A4 Single Hung. Pairing multi-pane insulation down to 0.16 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
How does a 3x5 ft A4 Single Hung window perform under a 40 deg F temperature drop?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), A4 Single Hung at U 0.16 conducts 96.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
When should a buyer skip Vinylmax LLC A4 Single Hung and compare alternatives?
Cold-climate owners needing prescriptive U <= 0.22 should pass on A4 Single Hung options exceeding U 0.22. Additionally, do not order Single-Hung (VSSH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Does A4 Single Hung meet Southern hot-climate SHGC caps (<= 0.23)?
Across Northern, North-Central, South-Central, Southern, 2,361 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Vinylmax LLC A4 Single Hung, while total line SHGC reaches 0.50 in colder packages.
Are all 3,907 A4 Single Hung configurations ENERGY STAR Most Efficient?
No. Exactly 565 of 3,907 configurations (14.5%) earn ENERGY STAR Most Efficient status in A4 Single Hung; the remaining standard v7.0 options pass base zone limits only.
How do the 25C sunset and pre-1978 Lead RRP rules affect A4 Single Hung?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current A4 Single Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How do you cross-check NFRC VIM and product line VIM-M-51 on delivery?
Verify NFRC ID VIM and series VIM-M-51 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Vinylmax LLC A4 Single Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)