Skip to main content
Window · Vinyl Frame NFRC DRU · Product Line DRU-K-7 ENERGY STAR Most Efficient Eligible

DRUTEX S.A. — IGLO ENERGY Classic Casement · Casement Windows

Positioning #250/1,352 in certified Window, DRUTEX S.A. IGLO ENERGY Classic Casement pairs Vinyl frame construction with 4,020 glazing options rated between 0.03 and 0.30 SHGC across Northern, North-Central, South-Central, Southern. Across 40 certified DRUTEX S.A. product families, its thermal resistance spans 0.16 to 0.32 U-Factor and the line includes 1,742 ENERGY STAR Most Efficient packages (43.3% of line).

Min U-Factor
0.16
SHGC Range
0.03-0.30
Certified Options
4,020
Category Standing
#250 of 1,352

How does DRUTEX S.A. IGLO ENERGY Classic Casement compare thermally against Window peers?

DRUTEX S.A. IGLO ENERGY Classic Casement achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. IGLO ENERGY Classic CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing IGLO ENERGY Classic Casement (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

IGLO ENERGY Classic Casement Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows DRUTEX S.A. IGLO ENERGY Classic Casement standing at #250 of 1,352 certified Window product series, tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%. Comparing Vinyl profiles alone (median 0.19) shows -0.03 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.03 to 0.30) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 1,742 configurations meet ENERGY STAR Most Efficient criteria while 1,241 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2023-04-03 licensing and 2023-11-15 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4,020 certified glazing combinations for IGLO ENERGY Classic Casement (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 1,241 packages (382 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 3,158 packages (1,043 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 3,394 packages (970 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 3,753 packages (1,669 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Vinylmax LLC — A4 Single Hung Vinyl 0.16 0.11 3,907
MI Windows and Doors, LLC — 1653 Polyvinyl Chloride (PVC) Double Hung Window Vinyl 0.16 0.06 4,599
Vinylmax LLC — A4 Single Slider Vinyl 0.16 0.11 4,620
Great Day Improvements, LLC — 8200/820043 Horizontal Slider Vinyl 0.16 0.15 5,498
Paradigm Window Solutions — 8351 Casement Vinyl 0.16 0.12 2,533

What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO ENERGY Classic Casement appear below.

How efficient is DRUTEX S.A. IGLO ENERGY Classic Casement compared with peer Window models?

Across 4,020 tested NFRC glazing configurations, DRUTEX S.A. IGLO ENERGY Classic Casement with Vinyl framing and Casement Single-Vent (CSSV) style reaches a 0.16 minimum U-Factor and 0.03-0.30 SHGC band. It places #250 among 1,352 Window series—top 26.7%.

Can homeowners install IGLO ENERGY Classic Casement in cold Northern ENERGY STAR counties?

Prescriptive Northern compliance covers 1,241 IGLO ENERGY Classic Casement packages (U floor 0.16, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from IGLO ENERGY Classic Casement's 0.16 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.16 U-Factor yields 96.0 BTU/hr conductive transfer (-27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make IGLO ENERGY Classic Casement the wrong window or door choice?

Skip IGLO ENERGY Classic Casement if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO ENERGY Classic Casement options exceeding U 0.22.

How many IGLO ENERGY Classic Casement glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 3,753 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside DRUTEX S.A. IGLO ENERGY Classic Casement, while total line SHGC reaches 0.30 in colder packages.

Which package tier in IGLO ENERGY Classic Casement holds Most Efficient recognition?

Only 1,742 options out of 4,020 (43.3%) meet tighter Most Efficient U-Factor and SHGC thresholds in DRUTEX S.A. IGLO ENERGY Classic Casement, usually requiring triple-pane or upgraded Low-E coatings.

What federal compliance checks govern 2026 IGLO ENERGY Classic Casement window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify IGLO ENERGY Classic Casement glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.16-0.32, SHGC 0.03-0.30) against permit drawings for line DRU-K-7. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO ENERGY Classic Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros