MI Windows and Doors, LLC — 1653 Polyvinyl Chloride (PVC) Double Hung Window · Double Hung
Across 48 MI Windows and Doors, LLC certified families, 1653 Polyvinyl Chloride (PVC) Double Hung Window supplies 4,599 Double Hung configurations starting at 0.16 U-Factor and 0.06 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.49 SHGC. Its thermal floor ranks #250 of 1,352 category entries—0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.16
- SHGC Range
- 0.06-0.49
- Certified Options
- 4,599
- Category Standing
- #250 of 1,352
How does MI Windows and Doors, LLC 1653 Polyvinyl Chloride (PVC) Double Hung Window compare thermally against Window peers?
MI Windows and Doors, LLC 1653 Polyvinyl Chloride (PVC) Double Hung Window achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 48 certified MI Windows and Doors, LLC series, this Double Hung offers a 0.16 U-Factor adjustment span between 0.32 entry options and 0.16 top-performing glazing. Category standing is #250/1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%).
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 781 configurations meet ENERGY STAR Most Efficient criteria while 857 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-09-11 licensing and 2024-02-29 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 4,599 certified glazing combinations for 1653 Polyvinyl Chloride (PVC) Double Hung Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 857 packages (306 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 2,452 packages (577 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 2,899 packages (425 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 3,397 packages (593 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Vinylmax LLC — A4 Single Slider | Vinyl | 0.16 | 0.11 | 4,620 |
| DRUTEX S.A. — IGLO ENERGY Classic Casement | Vinyl | 0.16 | 0.03 | 4,020 |
| Vinylmax LLC — A4 Single Hung | Vinyl | 0.16 | 0.11 | 3,907 |
| Great Day Improvements, LLC — 8200/820043 Horizontal Slider | Vinyl | 0.16 | 0.15 | 5,498 |
| DRUTEX S.A. — IGLO ENERGY Classic Tilt Turn | Vinyl | 0.16 | 0.04 | 3,652 |
What other certified series does MI Windows and Doors, LLC produce?
Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.12–0.32 · 8,307 certified options.
9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window
U-Factor 0.13–0.32 · 6,920 certified options.
1615T Polyvinyl Chloride (PVC) Transom
U-Factor 0.14–0.31 · 3,234 certified options.
3075/3065 Direct Set Picture Window
U-Factor 0.14–0.32 · 35,308 certified options.
SR CASE PW Vinyl Fixed Window
U-Factor 0.14–0.31 · 5,254 certified options.
1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.15–0.32 · 11,774 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 1653 Polyvinyl Chloride (PVC) Double Hung Window appear below.
What thermal performance numbers separate MI Windows and Doors, LLC 1653 Polyvinyl Chloride (PVC) Double Hung Window from peers?
Testing puts MI Windows and Doors, LLC 1653 Polyvinyl Chloride (PVC) Double Hung Window at rank #250 of 1,352 Window entries with U 0.16 to 0.32 across 4,599 configurations. Solar heat gain ranges between 0.06 and 0.49 across Northern, North-Central, South-Central, Southern.
Can homeowners install 1653 Polyvinyl Chloride (PVC) Double Hung Window in cold Northern ENERGY STAR counties?
Yes, 857 packages satisfy Northern ENERGY STAR Version 7.0 rules in 1653 Polyvinyl Chloride (PVC) Double Hung Window. Pairing multi-pane insulation down to 0.16 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
How does a 3x5 ft 1653 Polyvinyl Chloride (PVC) Double Hung Window window perform under a 40 deg F temperature drop?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.16 U-Factor yields 96.0 BTU/hr conductive transfer (-27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
What are the practical limitations of specifying 1653 Polyvinyl Chloride (PVC) Double Hung Window?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 1653 Polyvinyl Chloride (PVC) Double Hung Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.
Can you install MI Windows and Doors, LLC 1653 Polyvinyl Chloride (PVC) Double Hung Window in Southern or South-Central zones?
Across Northern, North-Central, South-Central, Southern, 3,397 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside MI Windows and Doors, LLC 1653 Polyvinyl Chloride (PVC) Double Hung Window, while total line SHGC reaches 0.49 in colder packages.
What glazing share inside 1653 Polyvinyl Chloride (PVC) Double Hung Window qualifies as Most Efficient?
Only 781 options out of 4,599 (17.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in MI Windows and Doors, LLC 1653 Polyvinyl Chloride (PVC) Double Hung Window, usually requiring triple-pane or upgraded Low-E coatings.
What 2026 federal tax credit and Lead RRP rules apply to 1653 Polyvinyl Chloride (PVC) Double Hung Window?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 1653 Polyvinyl Chloride (PVC) Double Hung Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How do you cross-check NFRC MEI and product line MEI-A-229 on delivery?
Confirm both the paper NFRC label and permanent corner glass etch match line MEI-A-229 and NFRC ID MEI before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 1653 Polyvinyl Chloride (PVC) Double Hung Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)