Skip to main content
Window · Vinyl Frame NFRC DRU · Product Line DRU-K-8 ENERGY STAR Most Efficient Eligible

DRUTEX S.A. — IGLO ENERGY Classic Transom · Awning (Projected)

EPA ENERGY STAR Version 7.0 certifies 4,044 variants inside DRUTEX S.A. IGLO ENERGY Classic Transom, combining Vinyl frame construction with U-Factors spanning 0.18 to 0.32 and SHGC 0.03 to 0.29. Qualifying for Northern, North-Central, South-Central, Southern, this Awning, Projected family places #477 of 1,352 among 1,352 Window families and posts 0.01 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.18
SHGC Range
0.03-0.29
Certified Options
4,044
Category Standing
#477 of 1,352

How does DRUTEX S.A. IGLO ENERGY Classic Transom compare thermally against Window peers?

DRUTEX S.A. IGLO ENERGY Classic Transom achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. IGLO ENERGY Classic TransomHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing IGLO ENERGY Classic Transom (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

IGLO ENERGY Classic Transom Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 40 certified DRUTEX S.A. series, this Awning, Projected offers a 0.14 U-Factor adjustment span between 0.32 entry options and 0.18 top-performing glazing. Category standing is #477/1,352 (tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%).

Climate coverage for DRUTEX S.A. IGLO ENERGY Classic Transom spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 1,715 configurations meet ENERGY STAR Most Efficient criteria while 1,234 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.18 U-Factor yields 108.0 BTU/hr transfer (-24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2023-04-03 licensing and 2024-05-16 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4,044 certified glazing combinations for IGLO ENERGY Classic Transom (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 1,234 packages (319 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 3,235 packages (888 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 3,466 packages (836 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 3,784 packages (1,663 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Vinylmax LLC — CA55/CA74 Casement Vinyl 0.18 0.13 3,415
Windsor Windows and Doors — Next Dimension Single Slider Vinyl 0.18 0.12 3,241
Amsco Windows — VZ1 Hampton Casement Vinyl 0.18 0.09 3,164
Amsco Windows — VZ1 Hampton Awning Vinyl 0.18 0.09 3,114
MI Windows and Doors, LLC — 1615 Polyvinyl Chloride (PVC) Sidelite Vinyl 0.18 0.06 3,045

What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO ENERGY Classic Transom appear below.

Where does DRUTEX S.A. IGLO ENERGY Classic Transom stand thermally among ENERGY STAR Window lines?

Built with Vinyl framing in Projected Awning (PRAW) style, DRUTEX S.A. IGLO ENERGY Classic Transom offers 4,044 Version 7.0 configurations from U 0.18 up to 0.32, posting -0.02 against the Window median of 0.20 with 1,715 Most Efficient picks.

How does DRUTEX S.A. IGLO ENERGY Classic Transom satisfy Version 7.0 Northern criteria?

Yes. 1,234 packages in DRUTEX S.A. IGLO ENERGY Classic Transom clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

How does a 3x5 ft IGLO ENERGY Classic Transom window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.18 U-Factor yields 108.0 BTU/hr conductive transfer (-18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Who should NOT choose DRUTEX S.A. IGLO ENERGY Classic Transom for a residential project?

Do not specify IGLO ENERGY Classic Transom without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO ENERGY Classic Transom options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Is IGLO ENERGY Classic Transom suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 3,784 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside DRUTEX S.A. IGLO ENERGY Classic Transom, while total line SHGC reaches 0.29 in colder packages.

Which package tier in IGLO ENERGY Classic Transom holds Most Efficient recognition?

Not every package qualifies: 1,715 of 4,044 IGLO ENERGY Classic Transom glazing builds earn Most Efficient recognition (42.4%), while other variants sit on the standard Version 7.0 tier.

How do the 25C sunset and pre-1978 Lead RRP rules affect IGLO ENERGY Classic Transom?

Any IGLO ENERGY Classic Transom purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on IGLO ENERGY Classic Transom?

Confirm both the paper NFRC label and permanent corner glass etch match line DRU-K-8 and NFRC ID DRU before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO ENERGY Classic Transom come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros