Window · Vinyl Frame NFRC PGT · Product Line PGT-A-234 ENERGY STAR Most Efficient Eligible

PGT Industries — SH5400/5500 · Single Hung

PGT Industries engineered the SH5400/5500 Single Hung line for Northern, North-Central, South-Central, Southern, certifying 9,241 glass-spacer combinations from 0.17 to 0.32 U-Factor and 0.09 to 0.44 SHGC. Relative to other Vinyl models tracked under NFRC PGT, its minimum U-Factor is 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.09-0.44
Certified Options
9,241
Category Standing
#362 of 1,352

How does PGT Industries SH5400/5500 compare thermally against Window peers?

PGT Industries SH5400/5500 achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. SH5400/5500Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing SH5400/5500 (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

SH5400/5500 Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places PGT Industries SH5400/5500 at rank #362 of 1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.09-0.44 band.

Mapping NFRC SHGC values (0.09 to 0.44) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 114 configurations meet ENERGY STAR Most Efficient criteria while 125 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2025-07-31. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.17 conducts 102.0 BTU/hr (-30.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 9,241 certified glazing combinations for SH5400/5500 (NFRC PGT) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 125 packages (32 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 225 packages (68 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,496 packages (44 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 9,153 packages (86 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does PGT Industries produce?

Compare other active PGT Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to PGT Industries SH5400/5500 appear below.

How efficient is PGT Industries SH5400/5500 compared with peer Window models?

Across 9,241 tested NFRC glazing configurations, PGT Industries SH5400/5500 with Vinyl framing and Single-Hung (VSSH) style reaches a 0.17 minimum U-Factor and 0.09-0.44 SHGC band. It places #362 among 1,352 Window series—top 35.2%.

How does PGT Industries SH5400/5500 satisfy Version 7.0 Northern criteria?

Yes. 125 packages in PGT Industries SH5400/5500 clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

How much winter heat loss does SH5400/5500 conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.17 U-Factor yields 102.0 BTU/hr conductive transfer (-22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What are the practical limitations of specifying SH5400/5500?

Cold-climate owners needing prescriptive U <= 0.22 should pass on SH5400/5500 options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in SH5400/5500?

Across Northern, North-Central, South-Central, Southern, 9,153 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside PGT Industries SH5400/5500, while total line SHGC reaches 0.44 in colder packages.

Are all 9,241 SH5400/5500 configurations ENERGY STAR Most Efficient?

EPA lists 114 Most Efficient options (1.2% share) inside PGT Industries SH5400/5500, out of 9,241 total Version 7.0 entries.

What 2026 federal tax credit and Lead RRP rules apply to SH5400/5500?

Any SH5400/5500 purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC PGT and product line PGT-A-234 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line PGT-A-234 and NFRC ID PGT before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for PGT Industries SH5400/5500 come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros