Skip to main content
Window · Vinyl Frame NFRC WCW · Product Line WCW-M-32 ENERGY STAR Most Efficient Eligible

Wincore Window Company, LLC — 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window · Awning (Projected)

Across 23 Wincore Window Company, LLC certified families, 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window supplies 6,256 Awning, Projected configurations starting at 0.17 U-Factor and 0.08 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.41 SHGC. Its thermal floor ranks #362 of 1,352 category entries—0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.08-0.41
Certified Options
6,256
Category Standing
#362 of 1,352

How does Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window compare thermally against Window peers?

Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window standing at #362 of 1,352 certified Window product series, tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%. Comparing Vinyl profiles alone (median 0.19) shows -0.02 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. 458 configurations meet ENERGY STAR Most Efficient criteria while 416 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-08-23 licensing and 2024-11-25 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 6,256 certified glazing combinations for 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window (NFRC WCW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 416 packages (24 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 2,654 packages (134 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 4,915 packages (122 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 5,928 packages (446 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Vinylmax LLC — DHA4 Double Hung Vinyl 0.17 0.14 7,745
PGT Industries — HR5410/5510 Vinyl 0.17 0.08 8,277
MI Windows and Doors, LLC — SR SH | DH SP Vinyl Fixed Specialty Window Vinyl 0.17 0.09 4,152
PGT Industries — SH5400/5500 Vinyl 0.17 0.09 9,241
Amsco Windows — VZ1 Hampton PM Fixed Vinyl 0.17 0.11 2,764

What other certified series does Wincore Window Company, LLC produce?

Compare other active Wincore Window Company, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window appear below.

What U-Factor and SHGC range does Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window achieve?

Across 6,256 tested NFRC glazing configurations, Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window with Vinyl framing and Projected Awning (PRAW) style reaches a 0.17 minimum U-Factor and 0.08-0.41 SHGC band. It places #362 among 1,352 Window series—top 35.2%.

How does Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window satisfy Version 7.0 Northern criteria?

Yes, 416 packages satisfy Northern ENERGY STAR Version 7.0 rules in 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window. Pairing multi-pane insulation down to 0.17 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What BTU/hr heat transfer results from 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window's 0.17 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.17 U-Factor yields 102.0 BTU/hr conductive transfer (-22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What are the practical limitations of specifying 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window in Southern or South-Central zones?

Yes, 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window holds 5,928 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.08 SHGC in cooling climates.

Does 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 458 of 6,256 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window glazing builds earn Most Efficient recognition (7.3%), while other variants sit on the standard Version 7.0 tier.

Can homeowners claim Form 5695 credits on Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Wincore Window Company, LLC upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do you cross-check NFRC WCW and product line WCW-M-32 on delivery?

Match the NFRC thermal sticker for code WCW and line WCW-M-32 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)