Door · Composite / Steel / Wood Frame NFRC WCW · Product Line WCW-M-17

Wincore Window Company, LLC — Fiberglass Entry Door · Swinging Entry Door (Single)

With a minimum U-Factor of 0.16—-0.05 compared against the 0.21 Door median—Wincore Window Company, LLC Fiberglass Entry Door spans 11,717 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code WCW, the Composite / Steel / Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.00 and 0.31.

Min U-Factor
0.16
SHGC Range
0.00-0.31
Certified Options
11,717
Category Standing
#29 of 268

How does Wincore Window Company, LLC Fiberglass Entry Door compare thermally against Door peers?

Wincore Window Company, LLC Fiberglass Entry Door achieves a 0.16 thermal floor across Door lines, placing #29 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Fiberglass Entry DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Fiberglass Entry Door (U 0.16).28<=0.15650.16-0.18This model: U 0.16510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Fiberglass Entry Door Cohort StandingMin U-Factor 0.16 stands at rank #29 of 268, outperforming 79.9% of peers.Min U-Factor 0.16Rank #29 of 268 (79.9% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 23 certified Wincore Window Company, LLC series, this Swinging Entry Door, Single offers a 0.12 U-Factor adjustment span between 0.28 entry options and 0.16 top-performing glazing. Category standing is #29/268 (tied with 25 others at 0.16, more insulating than 79.9% of Door lines, top 20.1%).

Mapping NFRC SHGC values (0.00 to 0.31) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 10,460 combinations qualify in the Northern Zone alongside 11,622 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Lifecycle documentation anchors WCW to 2025-01-23 certification (FENSTAR issued 2018-08-23). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 96.0 BTU/hr conductive loss (-27.3% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 11,717 certified glazing combinations for Fiberglass Entry Door (NFRC WCW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 10,460 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 10,460 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 11,622 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 11,622 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Plastpro Inc. — Plastpro Fiberglass Entry Door Composite / Steel / Wood 0.16 0.00 11,704
MI Windows and Doors, LLC — VX4520/VX4530/VX4540 Multi Slide Door Vinyl 0.16 0.09 10,215
ProVia LLC — Thermally Improved 20 Gauge Steel Entry Door Composite / Steel / Vinyl / Wood 0.16 0.01 6,900
Milgard Manufacturing, Inc. — 8621.8631 Sliding Glass Door Vinyl 0.16 0.09 6,471
Quaker Window Products — V300/V600 Outswing Door Vinyl 0.16 0.08 16,974

What other certified series does Wincore Window Company, LLC produce?

Compare other active Wincore Window Company, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wincore Window Company, LLC Fiberglass Entry Door appear below.

What thermal performance numbers separate Wincore Window Company, LLC Fiberglass Entry Door from peers?

Testing puts Wincore Window Company, LLC Fiberglass Entry Door at rank #29 of 268 Door entries with U 0.16 to 0.28 across 11,717 configurations. Solar heat gain ranges between 0.00 and 0.31 across Northern, North-Central, South-Central, Southern.

Is Fiberglass Entry Door approved for Northern Zone heating climates?

Yes. 10,460 packages in Wincore Window Company, LLC Fiberglass Entry Door clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.28.

How much winter heat loss does Fiberglass Entry Door conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.16 U-Factor yields 96.0 BTU/hr conductive transfer (-27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Wincore Window Company, LLC Fiberglass Entry Door?

Skip Fiberglass Entry Door if local historic preservation boards prohibit Composite / Steel / Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Fiberglass Entry Door options exceeding U 0.22.

Is Fiberglass Entry Door suitable for sunbelt cooling-dominated homes?

Yes, Fiberglass Entry Door holds 11,622 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.00 SHGC in cooling climates.

Are all 11,717 Fiberglass Entry Door configurations ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 11,717 Fiberglass Entry Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What 2026 federal tax credit and Lead RRP rules apply to Fiberglass Entry Door?

Any Fiberglass Entry Door purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC WCW and product line WCW-M-17 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line WCW-M-17 and NFRC ID WCW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Wincore Window Company, LLC Fiberglass Entry Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros