Skip to main content
Door · Composite / Steel / Vinyl / Wood Frame NFRC PRD · Product Line PRD-N-88

ProVia LLC — Thermally Improved 20 Gauge Steel Entry Door · Swinging Entry Door (Single)

Across 21 ProVia LLC certified families, Thermally Improved 20 Gauge Steel Entry Door supplies 6,900 Swinging Entry Door, Single configurations starting at 0.16 U-Factor and 0.01 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.25 SHGC. Its thermal floor ranks #29 of 268 category entries—0.05 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.16
SHGC Range
0.01-0.25
Certified Options
6,900
Category Standing
#29 of 268

How does ProVia LLC Thermally Improved 20 Gauge Steel Entry Door compare thermally against Door peers?

ProVia LLC Thermally Improved 20 Gauge Steel Entry Door achieves a 0.16 thermal floor across Door lines, placing #29 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Thermally Improved 20 Gauge Steel Entry DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Thermally Improved 20 Gauge Steel Entry Door (U 0.16).28<=0.15650.16-0.18This model: U 0.16510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Thermally Improved 20 Gauge Steel Entry Door Cohort StandingMin U-Factor 0.16 stands at rank #29 of 268, outperforming 79.9% of peers.Min U-Factor 0.16Rank #29 of 268 (79.9% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 21 certified ProVia LLC series, this Swinging Entry Door, Single offers a 0.12 U-Factor adjustment span between 0.28 entry options and 0.16 top-performing glazing. Category standing is #29/268 (tied with 25 others at 0.16, more insulating than 79.9% of Door lines, top 20.1%).

Mapping NFRC SHGC values (0.01 to 0.25) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 5,422 combinations qualify in the Northern Zone alongside 6,899 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2023-11-15 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 6,900 certified glazing combinations for Thermally Improved 20 Gauge Steel Entry Door (NFRC PRD) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 5,422 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 5,422 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 6,899 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 6,899 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Milgard Manufacturing, Inc. — 8621.8631 Sliding Glass Door Vinyl 0.16 0.09 6,471
JELD-WEN, inc. — JWC7200 Vinyl Sliding Door Aluminum / Vinyl 0.16 0.13 6,103
MI Windows and Doors, LLC — VX4520/VX4530/VX4540 Multi Slide Door Vinyl 0.16 0.09 10,215
EnergyWall Window — 8480/7480/3080 Patio Door Vinyl 0.16 0.15 3,179
Polaris Windows and Doors — 8480/7480/3080 Patio Door Vinyl 0.16 0.15 3,179

What other certified series does ProVia LLC produce?

Compare other active ProVia LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to ProVia LLC Thermally Improved 20 Gauge Steel Entry Door appear below.

How efficient is ProVia LLC Thermally Improved 20 Gauge Steel Entry Door compared with peer Door models?

Built with Composite / Steel / Vinyl / Wood framing in Entry Door Single-Lite (EDSL) style, ProVia LLC Thermally Improved 20 Gauge Steel Entry Door offers 6,900 Version 7.0 configurations from U 0.16 up to 0.28, posting -0.05 against the Door median of 0.21 with 0 Most Efficient picks.

How does ProVia LLC Thermally Improved 20 Gauge Steel Entry Door satisfy Version 7.0 Northern criteria?

Cold-climate buyers get 5,422 compliant Northern packages inside Thermally Improved 20 Gauge Steel Entry Door, reaching down to U 0.16. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

How do you calculate winter heat conduction for ProVia LLC Thermally Improved 20 Gauge Steel Entry Door?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.16 U-Factor yields 96.0 BTU/hr conductive transfer (-27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip ProVia LLC Thermally Improved 20 Gauge Steel Entry Door and compare alternatives?

Skip Thermally Improved 20 Gauge Steel Entry Door if local historic preservation boards prohibit Composite / Steel / Vinyl / Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Thermally Improved 20 Gauge Steel Entry Door options exceeding U 0.22.

Is Thermally Improved 20 Gauge Steel Entry Door suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 6,899 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside ProVia LLC Thermally Improved 20 Gauge Steel Entry Door, while total line SHGC reaches 0.25 in colder packages.

Which package tier in Thermally Improved 20 Gauge Steel Entry Door holds Most Efficient recognition?

Thermally Improved 20 Gauge Steel Entry Door holds zero Most Efficient entries across its 6,900 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

Can homeowners claim Form 5695 credits on ProVia LLC Thermally Improved 20 Gauge Steel Entry Door in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Thermally Improved 20 Gauge Steel Entry Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify Thermally Improved 20 Gauge Steel Entry Door after sticker removal?

Verify NFRC ID PRD and series PRD-N-88 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for ProVia LLC Thermally Improved 20 Gauge Steel Entry Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)