Skip to main content
Door · Composite / Steel / Wood Frame NFRC NPC · Product Line NPC-M-1

Plastpro Inc. — Plastpro Fiberglass Entry Door · Swinging Entry Door (Single)

Plastpro Inc. engineered the Plastpro Fiberglass Entry Door Swinging Entry Door, Single line for Northern, North-Central, South-Central, Southern, certifying 11,704 glass-spacer combinations from 0.16 to 0.28 U-Factor and 0.00 to 0.31 SHGC. Relative to other Composite / Steel / Wood models tracked under NFRC NPC, its minimum U-Factor is matches the 0.16 Btu/hr·ft²·°F median.

Min U-Factor
0.16
SHGC Range
0.00-0.31
Certified Options
11,704
Category Standing
#29 of 268

How does Plastpro Inc. Plastpro Fiberglass Entry Door compare thermally against Door peers?

Plastpro Inc. Plastpro Fiberglass Entry Door achieves a 0.16 thermal floor across Door lines, placing #29 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Plastpro Fiberglass Entry DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Plastpro Fiberglass Entry Door (U 0.16).28<=0.15650.16-0.18This model: U 0.16510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Plastpro Fiberglass Entry Door Cohort StandingMin U-Factor 0.16 stands at rank #29 of 268, outperforming 79.9% of peers.Min U-Factor 0.16Rank #29 of 268 (79.9% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 268 ENERGY STAR v7.0 Door lines places Plastpro Inc. Plastpro Fiberglass Entry Door at rank #29 of 268 (tied with 25 others at 0.16, more insulating than 79.9% of Door lines, top 20.1%; cohort median 0.21). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.00-0.31 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 10,467 combinations qualify in the Northern Zone alongside 11,609 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-09-11 licensing and 2025-01-30 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 11,704 certified glazing combinations for Plastpro Fiberglass Entry Door (NFRC NPC) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 10,467 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 10,467 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 11,609 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 11,609 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Wincore Window Company, LLC — Fiberglass Entry Door Composite / Steel / Wood 0.16 0.00 11,717
MI Windows and Doors, LLC — VX4520/VX4530/VX4540 Multi Slide Door Vinyl 0.16 0.09 10,215
ProVia LLC — Thermally Improved 20 Gauge Steel Entry Door Composite / Steel / Vinyl / Wood 0.16 0.01 6,900
Milgard Manufacturing, Inc. — 8621.8631 Sliding Glass Door Vinyl 0.16 0.09 6,471
Quaker Window Products — V300/V600 Outswing Door Vinyl 0.16 0.08 16,974

What other certified series does Plastpro Inc. produce?

Compare other active Plastpro Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Plastpro Inc. Plastpro Fiberglass Entry Door appear below.

What thermal performance numbers separate Plastpro Inc. Plastpro Fiberglass Entry Door from peers?

Testing puts Plastpro Inc. Plastpro Fiberglass Entry Door at rank #29 of 268 Door entries with U 0.16 to 0.28 across 11,704 configurations. Solar heat gain ranges between 0.00 and 0.31 across Northern, North-Central, South-Central, Southern.

Does Plastpro Inc. Plastpro Fiberglass Entry Door qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 10,467 Plastpro Fiberglass Entry Door packages (U floor 0.16, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from Plastpro Fiberglass Entry Door's 0.16 minimum U-Factor?

At U 0.16, a standard 3x5 ft (15 sq ft) Plastpro Fiberglass Entry Door opening transfers 96.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -36.0 BTU/hr difference.

What homeowner profiles are a poor match for Plastpro Inc. Plastpro Fiberglass Entry Door?

Skip Plastpro Fiberglass Entry Door if local historic preservation boards prohibit Composite / Steel / Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Plastpro Fiberglass Entry Door options exceeding U 0.22.

Is Plastpro Fiberglass Entry Door suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 11,609 Southern-approved options within Plastpro Fiberglass Entry Door spanning SHGC down to 0.00. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does Plastpro Fiberglass Entry Door carry EPA Most Efficient certification across its lineup?

Zero glazing builds inside Plastpro Fiberglass Entry Door's 11,704 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

What federal compliance checks govern 2026 Plastpro Fiberglass Entry Door window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Plastpro Fiberglass Entry Door retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

Where are NFRC and IGCC identification marks located on Plastpro Fiberglass Entry Door?

Confirm both the paper NFRC label and permanent corner glass etch match line NPC-M-1 and NFRC ID NPC before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Plastpro Inc. Plastpro Fiberglass Entry Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros