Wincore Window Company, LLC — 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window · Casement Windows
Positioning #362/1,352 in certified Window, Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window pairs Vinyl frame construction with 6,278 glazing options rated between 0.08 and 0.41 SHGC across Northern, North-Central, South-Central, Southern. Across 23 certified Wincore Window Company, LLC product families, its thermal resistance spans 0.17 to 0.32 U-Factor and the line includes 540 ENERGY STAR Most Efficient packages (8.6% of line).
- Min U-Factor
- 0.17
- SHGC Range
- 0.08-0.41
- Certified Options
- 6,278
- Category Standing
- #362 of 1,352
How does Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window compare thermally against Window peers?
Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Vinyl cohort (0.19 median U-Factor), 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window reaches 0.17 on its lowest-conductivity package — #271 of 1,009 in Vinyl, tied with 82 others at 0.17, more insulating than 65.0% of Vinyl lines, top 35.0% (-0.02 vs Vinyl peers). Pairing NFRC ID WCW across multi-pane fills shifts U-Factor from 0.32 down toward 0.17.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 540 configurations meet ENERGY STAR Most Efficient criteria while 429 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-08-23 licensing and 2024-11-25 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 6,278 certified glazing combinations for 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window (NFRC WCW) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 429 packages (24 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 2,892 packages (133 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 4,969 packages (121 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 5,928 packages (528 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Vinylmax LLC — DHA4 Double Hung | Vinyl | 0.17 | 0.14 | 7,745 |
| PGT Industries — HR5410/5510 | Vinyl | 0.17 | 0.08 | 8,277 |
| MI Windows and Doors, LLC — SR SH | DH SP Vinyl Fixed Specialty Window | Vinyl | 0.17 | 0.09 | 4,152 |
| PGT Industries — SH5400/5500 | Vinyl | 0.17 | 0.09 | 9,241 |
| Amsco Windows — VZ1 Hampton PM Fixed | Vinyl | 0.17 | 0.11 | 2,764 |
What other certified series does Wincore Window Company, LLC produce?
Compare other active Wincore Window Company, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
7700, 8400, 8800 Picture Window
U-Factor 0.14–0.32 · 28,216 certified options.
5400, 7700 Casement Picture Window
U-Factor 0.15–0.32 · 16,031 certified options.
9400, 9700, 8800, 9800 Single Hung
U-Factor 0.15–0.32 · 189,040 certified options.
Fiberglass Entry Door
U-Factor 0.16–0.28 · 11,717 certified options.
5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window
U-Factor 0.17–0.32 · 6,256 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window appear below.
Where does Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window stand thermally among ENERGY STAR Window lines?
Built with Vinyl framing in Casement Single-Vent (CSSV) style, Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window offers 6,278 Version 7.0 configurations from U 0.17 up to 0.32, posting -0.03 against the Window median of 0.20 with 540 Most Efficient picks.
Which glazing options in Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window meet Northern climate limits?
Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window supplies 429 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.
How do you calculate winter heat conduction for Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window?
At U 0.17, a standard 3x5 ft (15 sq ft) 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.
When should a buyer skip Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window and compare alternatives?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
Does 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window meet Southern hot-climate SHGC caps (<= 0.23)?
Yes, 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window holds 5,928 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.08 SHGC in cooling climates.
Which package tier in 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window holds Most Efficient recognition?
Not every package qualifies: 540 of 6,278 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window glazing builds earn Most Efficient recognition (8.6%), while other variants sit on the standard Version 7.0 tier.
Can homeowners claim Form 5695 credits on Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window in 2026?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
How can homeowners confirm delivered Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window units match permits?
Verify NFRC ID WCW and series WCW-M-31 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Wincore Window Company, LLC 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)