Skip to main content
Window · Steel / Vinyl / Wood Frame NFRC WCW · Product Line WCW-M-18

Wincore Window Company, LLC — Plastpro Fiberglass Sidelite · Sidelite

Across 23 Wincore Window Company, LLC certified families, Plastpro Fiberglass Sidelite supplies 7,791 Sidelite configurations starting at 0.13 U-Factor and 0.00 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.33 SHGC. Its thermal floor ranks #36 of 1,352 category entries—0.07 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.13
SHGC Range
0.00-0.33
Certified Options
7,791
Category Standing
#36 of 1,352

How does Wincore Window Company, LLC Plastpro Fiberglass Sidelite compare thermally against Window peers?

Wincore Window Company, LLC Plastpro Fiberglass Sidelite achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Plastpro Fiberglass SideliteHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Plastpro Fiberglass Sidelite (U 0.13).249<=0.15This model: U 0.133140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Plastpro Fiberglass Sidelite Cohort StandingMin U-Factor 0.13 stands at rank #36 of 1,352, outperforming 94.7% of peers.Min U-Factor 0.13Rank #36 of 1,352 (94.7% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Wincore Window Company, LLC Plastpro Fiberglass Sidelite at rank #36 of 1,352 (tied with 35 others at 0.13, more insulating than 94.7% of Window lines, top 5.3%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.00-0.33 band.

Climate coverage for Wincore Window Company, LLC Plastpro Fiberglass Sidelite spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 7,361 combinations qualify in the Northern Zone alongside 7,629 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Data provenance links certification 2024-12-13 and FENSTAR license 2018-08-23 inside EPA Version 7.0 tables. Heat transfer computes to 78.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 7,791 certified glazing combinations for Plastpro Fiberglass Sidelite (NFRC WCW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 7,361 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 7,361 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 7,629 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 7,629 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Wincore Window Company, LLC produce?

Compare other active Wincore Window Company, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wincore Window Company, LLC Plastpro Fiberglass Sidelite appear below.

What thermal performance numbers separate Wincore Window Company, LLC Plastpro Fiberglass Sidelite from peers?

Wincore Window Company, LLC Plastpro Fiberglass Sidelite spans 7,791 certified configurations with U-Factors between 0.13 and 0.28 and SHGC values from 0.00 to 0.33. Ranked #36 of 1,352 Window families, it carries 0 Most Efficient options.

Is Plastpro Fiberglass Sidelite approved for Northern Zone heating climates?

Wincore Window Company, LLC Plastpro Fiberglass Sidelite supplies 7,361 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.28, so inspect the NFRC order sheet before purchase.

What conductive BTU/hr difference separates Plastpro Fiberglass Sidelite from the 0.22 Northern rule?

At U 0.13, a standard 3x5 ft (15 sq ft) Plastpro Fiberglass Sidelite opening transfers 78.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -54.0 BTU/hr difference.

When should a buyer skip Wincore Window Company, LLC Plastpro Fiberglass Sidelite and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Plastpro Fiberglass Sidelite options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Is Plastpro Fiberglass Sidelite suitable for sunbelt cooling-dominated homes?

Yes, Plastpro Fiberglass Sidelite holds 7,629 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.00 SHGC in cooling climates.

What glazing share inside Plastpro Fiberglass Sidelite qualifies as Most Efficient?

No. Zero of the 7,791 configurations in Wincore Window Company, LLC Plastpro Fiberglass Sidelite hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

How do the 25C sunset and pre-1978 Lead RRP rules affect Plastpro Fiberglass Sidelite?

Any Plastpro Fiberglass Sidelite purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

What permanent glass etch marks verify Plastpro Fiberglass Sidelite after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line WCW-M-18 and NFRC ID WCW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Wincore Window Company, LLC Plastpro Fiberglass Sidelite come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)