Skip to main content
Window · Vinyl Frame NFRC WCW · Product Line WCW-M-53 ENERGY STAR Most Efficient Eligible

Wincore Window Company, LLC — 9400, 9700, 8800, 9800 Single Hung · Single Hung

Positioning #136/1,352 in certified Window, Wincore Window Company, LLC 9400, 9700, 8800, 9800 Single Hung pairs Vinyl frame construction with 189,040 glazing options rated between 0.13 and 0.51 SHGC across Northern, North-Central, South-Central, Southern. Across 23 certified Wincore Window Company, LLC product families, its thermal resistance spans 0.15 to 0.32 U-Factor and the line includes 18,174 ENERGY STAR Most Efficient packages (9.6% of line).

Min U-Factor
0.15
SHGC Range
0.13-0.51
Certified Options
189,040
Category Standing
#136 of 1,352

How does Wincore Window Company, LLC 9400, 9700, 8800, 9800 Single Hung compare thermally against Window peers?

Wincore Window Company, LLC 9400, 9700, 8800, 9800 Single Hung achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 9400, 9700, 8800, 9800 Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 9400, 9700, 8800, 9800 Single Hung (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

9400, 9700, 8800, 9800 Single Hung Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 9400, 9700, 8800, 9800 Single Hung is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.15-0.32.

Regional qualification covers Northern, North-Central, South-Central, Southern. 18,174 configurations meet ENERGY STAR Most Efficient criteria while 21,232 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors WCW to 2025-09-18 certification (FENSTAR issued 2018-08-23). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 90.0 BTU/hr conductive loss (-31.8% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 189,040 certified glazing combinations for 9400, 9700, 8800, 9800 Single Hung (NFRC WCW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 21,232 packages (4,304 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 49,456 packages (12,231 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 106,739 packages (10,293 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 182,799 packages (16,236 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Great Lakes Window, Inc. — ComfortSmart Double Hung Vinyl 0.15 0.12 193,132
Associated Materials, Inc. — 3002 Double Slider Vinyl 0.15 0.06 156,271
Associated Materials, Inc. — 3001/3A01/3B01 Double Hung Vinyl 0.15 0.06 145,543
Great Lakes Window, Inc. — Consolidated Casement Vinyl 0.15 0.11 122,071
Great Lakes Window, Inc. — Consolidated Awning Vinyl 0.15 0.11 118,195

What other certified series does Wincore Window Company, LLC produce?

Compare other active Wincore Window Company, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wincore Window Company, LLC 9400, 9700, 8800, 9800 Single Hung appear below.

How efficient is Wincore Window Company, LLC 9400, 9700, 8800, 9800 Single Hung compared with peer Window models?

EPA ENERGY STAR v7.0 records 189,040 configurations for Wincore Window Company, LLC 9400, 9700, 8800, 9800 Single Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.15 versus a 0.20 Window median. Only 18,174 options earn Most Efficient status.

Can homeowners install 9400, 9700, 8800, 9800 Single Hung in cold Northern ENERGY STAR counties?

Cold-climate buyers get 21,232 compliant Northern packages inside 9400, 9700, 8800, 9800 Single Hung, reaching down to U 0.15. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How do you calculate winter heat conduction for Wincore Window Company, LLC 9400, 9700, 8800, 9800 Single Hung?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 90.0 BTU/hr on 9400, 9700, 8800, 9800 Single Hung's lowest-U package (0.15), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

What homeowner profiles are a poor match for Wincore Window Company, LLC 9400, 9700, 8800, 9800 Single Hung?

Do not specify 9400, 9700, 8800, 9800 Single Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 9400, 9700, 8800, 9800 Single Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Can you install Wincore Window Company, LLC 9400, 9700, 8800, 9800 Single Hung in Southern or South-Central zones?

Yes, 9400, 9700, 8800, 9800 Single Hung holds 182,799 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.13 SHGC in cooling climates.

Which package tier in 9400, 9700, 8800, 9800 Single Hung holds Most Efficient recognition?

Only 18,174 options out of 189,040 (9.6%) meet tighter Most Efficient U-Factor and SHGC thresholds in Wincore Window Company, LLC 9400, 9700, 8800, 9800 Single Hung, usually requiring triple-pane or upgraded Low-E coatings.

What federal compliance checks govern 2026 9400, 9700, 8800, 9800 Single Hung window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 9400, 9700, 8800, 9800 Single Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify 9400, 9700, 8800, 9800 Single Hung after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code WCW and product line WCW-M-53, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Wincore Window Company, LLC 9400, 9700, 8800, 9800 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros