Great Lakes Window, Inc. — ComfortSmart Double Hung · Double Hung
EPA ENERGY STAR Version 7.0 certifies 193,132 variants inside Great Lakes Window, Inc. ComfortSmart Double Hung, combining Vinyl frame construction with U-Factors spanning 0.15 to 0.32 and SHGC 0.12 to 0.54. Qualifying for Northern, North-Central, South-Central, Southern, this Double Hung family places #136 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.
- Min U-Factor
- 0.15
- SHGC Range
- 0.12-0.54
- Certified Options
- 193,132
- Category Standing
- #136 of 1,352
How does Great Lakes Window, Inc. ComfortSmart Double Hung compare thermally against Window peers?
Great Lakes Window, Inc. ComfortSmart Double Hung achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), ComfortSmart Double Hung is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.15-0.32.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 19,176 configurations meet ENERGY STAR Most Efficient criteria while 37,503 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Lifecycle documentation anchors GLW to 2026-09-22 certification (FENSTAR issued 2018-09-11). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 90.0 BTU/hr conductive loss (-31.8% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 193,132 certified glazing combinations for ComfortSmart Double Hung (NFRC GLW) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 37,503 packages (5,968 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 82,141 packages (10,462 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 113,839 packages (7,408 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 145,738 packages (14,893 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Wincore Window Company, LLC — 9400, 9700, 8800, 9800 Single Hung | Vinyl | 0.15 | 0.13 | 189,040 |
| Associated Materials, Inc. — 3002 Double Slider | Vinyl | 0.15 | 0.06 | 156,271 |
| Associated Materials, Inc. — 3001/3A01/3B01 Double Hung | Vinyl | 0.15 | 0.06 | 145,543 |
| Associated Materials, Inc. — 0971 Casement | Vinyl | 0.15 | 0.10 | 45,043 |
| MI Windows and Doors, LLC — 3075 Casement | Vinyl | 0.15 | 0.08 | 39,389 |
What other certified series does Great Lakes Window, Inc. produce?
Compare other active Great Lakes Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
ComfortSmart/ecoSmart - Special Shapes Fixed Window
U-Factor 0.13–0.32 · 18,122 certified options.
Consolidated Casement Fixed
U-Factor 0.13–0.32 · 123,982 certified options.
ComfortSmart Horizontal Slider
U-Factor 0.16–0.32 · 154,875 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Great Lakes Window, Inc. ComfortSmart Double Hung appear below.
What U-Factor and SHGC range does Great Lakes Window, Inc. ComfortSmart Double Hung achieve?
Testing puts Great Lakes Window, Inc. ComfortSmart Double Hung at rank #136 of 1,352 Window entries with U 0.15 to 0.32 across 193,132 configurations. Solar heat gain ranges between 0.12 and 0.54 across Northern, North-Central, South-Central, Southern.
Is ComfortSmart Double Hung approved for Northern Zone heating climates?
Prescriptive Northern compliance covers 37,503 ComfortSmart Double Hung packages (U floor 0.15, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.
How do you calculate winter heat conduction for Great Lakes Window, Inc. ComfortSmart Double Hung?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.15 U-Factor yields 90.0 BTU/hr conductive transfer (-31.8% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
What homeowner profiles are a poor match for Great Lakes Window, Inc. ComfortSmart Double Hung?
Cold-climate owners needing prescriptive U <= 0.22 should pass on ComfortSmart Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
Does ComfortSmart Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?
Warm-climate homeowners have 145,738 Southern-approved options within ComfortSmart Double Hung spanning SHGC down to 0.12. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Which package tier in ComfortSmart Double Hung holds Most Efficient recognition?
No. Exactly 19,176 of 193,132 configurations (9.9%) earn ENERGY STAR Most Efficient status in ComfortSmart Double Hung; the remaining standard v7.0 options pass base zone limits only.
What 2026 federal tax credit and Lead RRP rules apply to ComfortSmart Double Hung?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 ComfortSmart Double Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
How do you cross-check NFRC GLW and product line GLW-M-126 on delivery?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code GLW and product line GLW-M-126, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Great Lakes Window, Inc. ComfortSmart Double Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)