Window · Vinyl Frame NFRC GLW · Product Line GLW-M-128 ENERGY STAR Most Efficient Eligible

Great Lakes Window, Inc. — ComfortSmart Picture Window · Picture Window

With a minimum U-Factor of 0.12—-0.08 compared against the 0.20 Window median—Great Lakes Window, Inc. ComfortSmart Picture Window spans 83,523 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code GLW, the Vinyl assembly includes 22,741 ENERGY STAR Most Efficient packages (27.2% of line) and offers SHGC packages between 0.13 and 0.61.

Min U-Factor
0.12
SHGC Range
0.13-0.61
Certified Options
83,523
Category Standing
#19 of 1,352

How does Great Lakes Window, Inc. ComfortSmart Picture Window compare thermally against Window peers?

Great Lakes Window, Inc. ComfortSmart Picture Window achieves a 0.12 thermal floor across Window lines, placing #19 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. ComfortSmart Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing ComfortSmart Picture Window (U 0.12).249<=0.15This model: U 0.123140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

ComfortSmart Picture Window Cohort StandingMin U-Factor 0.12 stands at rank #19 of 1,352, outperforming 97.4% of peers.Min U-Factor 0.12Rank #19 of 1,352 (97.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across ComfortSmart Picture Window spans 83,523 NFRC test records (GLW), ranking #19 of 1,352 Window families (tied with 16 others at 0.12, more insulating than 97.4% of Window lines, top 2.6%). Its 0.12 thermal floor compares at -0.07 against the Vinyl median (0.19).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 22,741 configurations meet ENERGY STAR Most Efficient criteria while 37,827 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.12 U-Factor yields 72.0 BTU/hr transfer (-60.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-09-11 licensing and 2026-09-14 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 83,523 certified glazing combinations for ComfortSmart Picture Window (NFRC GLW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 37,827 packages (10,800 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 50,353 packages (13,418 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 41,229 packages (8,904 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 46,827 packages (15,395 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.12 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Great Lakes Window, Inc. produce?

Compare other active Great Lakes Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Great Lakes Window, Inc. ComfortSmart Picture Window appear below.

What thermal performance numbers separate Great Lakes Window, Inc. ComfortSmart Picture Window from peers?

Testing puts Great Lakes Window, Inc. ComfortSmart Picture Window at rank #19 of 1,352 Window entries with U 0.12 to 0.32 across 83,523 configurations. Solar heat gain ranges between 0.13 and 0.61 across Northern, North-Central, South-Central, Southern.

Is ComfortSmart Picture Window approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 37,827 ComfortSmart Picture Window packages (U floor 0.12, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

How does a 3x5 ft ComfortSmart Picture Window window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.12 U-Factor yields 72.0 BTU/hr conductive transfer (-45.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What are the practical limitations of specifying ComfortSmart Picture Window?

Do not specify ComfortSmart Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on ComfortSmart Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

What Southern ENERGY STAR v7.0 options exist in ComfortSmart Picture Window?

Exactly 46,827 ComfortSmart Picture Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.13 rather than higher 0.61 glass.

Are all 83,523 ComfortSmart Picture Window configurations ENERGY STAR Most Efficient?

Only 22,741 options out of 83,523 (27.2%) meet tighter Most Efficient U-Factor and SHGC thresholds in Great Lakes Window, Inc. ComfortSmart Picture Window, usually requiring triple-pane or upgraded Low-E coatings.

What federal compliance checks govern 2026 ComfortSmart Picture Window window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Great Lakes Window, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify ComfortSmart Picture Window glass specs on job sites?

Verify NFRC ID GLW and series GLW-M-128 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Great Lakes Window, Inc. ComfortSmart Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)