Skip to main content
Window · Vinyl Frame NFRC GLW · Product Line GLW-M-114 ENERGY STAR Most Efficient Eligible

Great Lakes Window, Inc. — Consolidated Awning · Awning (Projected)

EPA ENERGY STAR Version 7.0 certifies 118,195 variants inside Great Lakes Window, Inc. Consolidated Awning, combining Vinyl frame construction with U-Factors spanning 0.15 to 0.32 and SHGC 0.11 to 0.49. Qualifying for Northern, North-Central, South-Central, Southern, this Awning, Projected family places #136 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.15
SHGC Range
0.11-0.49
Certified Options
118,195
Category Standing
#136 of 1,352

How does Great Lakes Window, Inc. Consolidated Awning compare thermally against Window peers?

Great Lakes Window, Inc. Consolidated Awning achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Consolidated AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Consolidated Awning (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Consolidated Awning Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 7 certified Great Lakes Window, Inc. series, this Awning, Projected offers a 0.17 U-Factor adjustment span between 0.32 entry options and 0.15 top-performing glazing. Category standing is #136/1,352 (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 14,051 configurations meet ENERGY STAR Most Efficient criteria while 21,943 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 90.0 BTU/hr (-31.8% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-09-11 and cert timestamp 2026-09-14.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 118,195 certified glazing combinations for Consolidated Awning (NFRC GLW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 21,943 packages (3,197 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 63,837 packages (7,242 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 77,534 packages (5,186 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 91,076 packages (11,904 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Associated Materials, Inc. — 3001/3A01/3B01 Double Hung Vinyl 0.15 0.06 145,543
Associated Materials, Inc. — 3002 Double Slider Vinyl 0.15 0.06 156,271
Wincore Window Company, LLC — 9400, 9700, 8800, 9800 Single Hung Vinyl 0.15 0.13 189,040
Associated Materials, Inc. — 0971 Casement Vinyl 0.15 0.10 45,043
MI Windows and Doors, LLC — 3075 Casement Vinyl 0.15 0.08 39,389

What other certified series does Great Lakes Window, Inc. produce?

Compare other active Great Lakes Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Great Lakes Window, Inc. Consolidated Awning appear below.

Where does Great Lakes Window, Inc. Consolidated Awning stand thermally among ENERGY STAR Window lines?

Built with Vinyl framing in Projected Awning (PRAW) style, Great Lakes Window, Inc. Consolidated Awning offers 118,195 Version 7.0 configurations from U 0.15 up to 0.32, posting -0.05 against the Window median of 0.20 with 14,051 Most Efficient picks.

Can homeowners install Consolidated Awning in cold Northern ENERGY STAR counties?

Yes, 21,943 packages satisfy Northern ENERGY STAR Version 7.0 rules in Consolidated Awning. Pairing multi-pane insulation down to 0.15 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How do you calculate winter heat conduction for Great Lakes Window, Inc. Consolidated Awning?

Using NFRC GLW U-Factor 0.15, a 15 sq ft Projected Awning (PRAW) assembly conducts 90.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-42.0 BTU/hr margin).

Which situations make Consolidated Awning the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Consolidated Awning options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Does Consolidated Awning meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 91,076 Consolidated Awning options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.11 rather than higher 0.49 glass.

Are all 118,195 Consolidated Awning configurations ENERGY STAR Most Efficient?

Not every package qualifies: 14,051 of 118,195 Consolidated Awning glazing builds earn Most Efficient recognition (11.9%), while other variants sit on the standard Version 7.0 tier.

What federal compliance checks govern 2026 Consolidated Awning window swaps?

Any Consolidated Awning purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC GLW and product line GLW-M-114 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code GLW and product line GLW-M-114, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Great Lakes Window, Inc. Consolidated Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros