Skip to main content
Window · Vinyl Frame NFRC ASO · Product Line ASO-A-31 ENERGY STAR Most Efficient Eligible

Associated Materials, Inc. — 0971 Casement · Casement Windows

Associated Materials, Inc. 0971 Casement is a Casement Windows assembly with a Vinyl frame that reaches a minimum U-Factor of 0.15 across 45,043 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #136 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.10 to 0.45.

Min U-Factor
0.15
SHGC Range
0.10-0.45
Certified Options
45,043
Category Standing
#136 of 1,352

How does Associated Materials, Inc. 0971 Casement compare thermally against Window peers?

Associated Materials, Inc. 0971 Casement achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 0971 CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 0971 Casement (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

0971 Casement Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Associated Materials, Inc. 0971 Casement standing at #136 of 1,352 certified Window product series, tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%. Comparing Vinyl profiles alone (median 0.19) shows -0.04 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. 8,169 configurations meet ENERGY STAR Most Efficient criteria while 7,074 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-09-13 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 90.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 45,043 certified glazing combinations for 0971 Casement (NFRC ASO) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 7,074 packages (2,231 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 19,676 packages (5,165 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 27,533 packages (4,478 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 39,999 packages (7,482 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
MI Windows and Doors, LLC — 3075 Casement Vinyl 0.15 0.08 39,389
Milgard Manufacturing, Inc. — 8540T2 Casement Vinyl 0.15 0.08 39,263
MI Windows and Doors, LLC — 3065 Awning Vinyl 0.15 0.08 38,931
Milgard Manufacturing, Inc. — 8440T2 Awning Vinyl 0.15 0.08 38,805
PGT Industries — PW5440/5540 Vinyl 0.15 0.07 25,346

What other certified series does Associated Materials, Inc. produce?

Compare other active Associated Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Associated Materials, Inc. 0971 Casement appear below.

What U-Factor and SHGC range does Associated Materials, Inc. 0971 Casement achieve?

EPA ENERGY STAR v7.0 records 45,043 configurations for Associated Materials, Inc. 0971 Casement covering Northern, North-Central, South-Central, Southern, dropping down to U 0.15 versus a 0.20 Window median. Only 8,169 options earn Most Efficient status.

Does Associated Materials, Inc. 0971 Casement qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 7,074 compliant Northern packages inside 0971 Casement, reaching down to U 0.15. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How does a 3x5 ft 0971 Casement window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.15 U-Factor yields 90.0 BTU/hr conductive transfer (-31.8% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Associated Materials, Inc. 0971 Casement and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 0971 Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in 0971 Casement?

Yes, 0971 Casement holds 39,999 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.10 SHGC in cooling climates.

Are all 45,043 0971 Casement configurations ENERGY STAR Most Efficient?

EPA lists 8,169 Most Efficient options (18.1% share) inside Associated Materials, Inc. 0971 Casement, out of 45,043 total Version 7.0 entries.

Do 2026 0971 Casement installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Associated Materials, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

Where are NFRC and IGCC identification marks located on 0971 Casement?

Inspectors match the temporary NFRC sticker (U 0.15-0.32, SHGC 0.10-0.45) against permit drawings for line ASO-A-31. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Associated Materials, Inc. 0971 Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros