Window · Vinyl Frame NFRC MEI · Product Line MEI-A-266 ENERGY STAR Most Efficient Eligible

MI Windows and Doors, LLC — 3075 Casement · Casement Windows

EPA ENERGY STAR Version 7.0 certifies 39,389 variants inside MI Windows and Doors, LLC 3075 Casement, combining Vinyl frame construction with U-Factors spanning 0.15 to 0.32 and SHGC 0.08 to 0.46. Qualifying for Northern, North-Central, South-Central, Southern, this Casement Windows family places #136 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.15
SHGC Range
0.08-0.46
Certified Options
39,389
Category Standing
#136 of 1,352

How does MI Windows and Doors, LLC 3075 Casement compare thermally against Window peers?

MI Windows and Doors, LLC 3075 Casement achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 3075 CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 3075 Casement (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

3075 Casement Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows MI Windows and Doors, LLC 3075 Casement standing at #136 of 1,352 certified Window product series, tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%. Comparing Vinyl profiles alone (median 0.19) shows -0.04 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.08 to 0.46) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 3,059 configurations meet ENERGY STAR Most Efficient criteria while 3,362 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.15 U-Factor yields 90.0 BTU/hr transfer (-42.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-09-11 licensing and 2026-07-30 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 39,389 certified glazing combinations for 3075 Casement (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 3,362 packages (509 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 20,143 packages (1,395 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 29,998 packages (1,144 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 36,373 packages (2,808 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Milgard Manufacturing, Inc. — 8540T2 Casement Vinyl 0.15 0.08 39,263
Milgard Manufacturing, Inc. — 8440T2 Awning Vinyl 0.15 0.08 38,805
Associated Materials, Inc. — 0971 Casement Vinyl 0.15 0.10 45,043
PGT Industries — PW5440/5540 Vinyl 0.15 0.07 25,346
Milgard Manufacturing, Inc. — 8520T2.8530T2.8570T2 Casement Vinyl 0.15 0.08 24,195

What other certified series does MI Windows and Doors, LLC produce?

Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 3075 Casement appear below.

How efficient is MI Windows and Doors, LLC 3075 Casement compared with peer Window models?

Across 39,389 tested NFRC glazing configurations, MI Windows and Doors, LLC 3075 Casement with Vinyl framing and Casement Single-Vent (CSSV) style reaches a 0.15 minimum U-Factor and 0.08-0.46 SHGC band. It places #136 among 1,352 Window series—top 18.4%.

Can homeowners install 3075 Casement in cold Northern ENERGY STAR counties?

Yes, 3,362 packages satisfy Northern ENERGY STAR Version 7.0 rules in 3075 Casement. Pairing multi-pane insulation down to 0.15 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What BTU/hr heat transfer results from 3075 Casement's 0.15 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 3075 Casement at U 0.15 conducts 90.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying 3075 Casement?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 3075 Casement options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

How many 3075 Casement glazing packages pass Southern solar-heat rules?

Yes. 36,373 Southern-certified options inside MI Windows and Doors, LLC 3075 Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.46 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 39,389 3075 Casement configurations ENERGY STAR Most Efficient?

Within 3075 Casement, 7.8% (3,059 of 39,389) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

Can homeowners claim Form 5695 credits on MI Windows and Doors, LLC 3075 Casement in 2026?

Any 3075 Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC MEI and product line MEI-A-266 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line MEI-A-266 and NFRC ID MEI before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 3075 Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros