Skip to main content
Window · Vinyl Frame NFRC ASO · Product Line ASO-A-89 ENERGY STAR Most Efficient Eligible

Associated Materials, Inc. — 3001/3A01/3B01 Double Hung · Double Hung

EPA ENERGY STAR Version 7.0 certifies 145,543 variants inside Associated Materials, Inc. 3001/3A01/3B01 Double Hung, combining Vinyl frame construction with U-Factors spanning 0.15 to 0.32 and SHGC 0.06 to 0.48. Qualifying for Northern, North-Central, South-Central, Southern, this Double Hung family places #136 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.15
SHGC Range
0.06-0.48
Certified Options
145,543
Category Standing
#136 of 1,352

How does Associated Materials, Inc. 3001/3A01/3B01 Double Hung compare thermally against Window peers?

Associated Materials, Inc. 3001/3A01/3B01 Double Hung achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 3001/3A01/3B01 Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 3001/3A01/3B01 Double Hung (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

3001/3A01/3B01 Double Hung Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 3001/3A01/3B01 Double Hung spans 145,543 NFRC test records (ASO), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at -0.04 against the Vinyl median (0.19).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 36,280 configurations meet ENERGY STAR Most Efficient criteria while 31,594 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-02-15. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.15 conducts 90.0 BTU/hr (-42.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 145,543 certified glazing combinations for 3001/3A01/3B01 Double Hung (NFRC ASO) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 31,594 packages (10,092 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 88,602 packages (22,001 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 86,258 packages (17,165 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 117,757 packages (31,444 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Great Lakes Window, Inc. — Consolidated Casement Vinyl 0.15 0.11 122,071
Great Lakes Window, Inc. — Consolidated Awning Vinyl 0.15 0.11 118,195
Wincore Window Company, LLC — 9400, 9700, 8800, 9800 Single Hung Vinyl 0.15 0.13 189,040
Great Lakes Window, Inc. — ComfortSmart Double Hung Vinyl 0.15 0.12 193,132
MI Windows and Doors, LLC — 3075 Casement Vinyl 0.15 0.08 39,389

What other certified series does Associated Materials, Inc. produce?

Compare other active Associated Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Associated Materials, Inc. 3001/3A01/3B01 Double Hung appear below.

Where does Associated Materials, Inc. 3001/3A01/3B01 Double Hung stand thermally among ENERGY STAR Window lines?

Testing puts Associated Materials, Inc. 3001/3A01/3B01 Double Hung at rank #136 of 1,352 Window entries with U 0.15 to 0.32 across 145,543 configurations. Solar heat gain ranges between 0.06 and 0.48 across Northern, North-Central, South-Central, Southern.

Is 3001/3A01/3B01 Double Hung approved for Northern Zone heating climates?

Cold-climate buyers get 31,594 compliant Northern packages inside 3001/3A01/3B01 Double Hung, reaching down to U 0.15. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What conductive BTU/hr difference separates 3001/3A01/3B01 Double Hung from the 0.22 Northern rule?

Using NFRC ASO U-Factor 0.15, a 15 sq ft Double-Hung (VSDH) assembly conducts 90.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-42.0 BTU/hr margin).

When should a buyer skip Associated Materials, Inc. 3001/3A01/3B01 Double Hung and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 3001/3A01/3B01 Double Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

How many 3001/3A01/3B01 Double Hung glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 117,757 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Associated Materials, Inc. 3001/3A01/3B01 Double Hung, while total line SHGC reaches 0.48 in colder packages.

What glazing share inside 3001/3A01/3B01 Double Hung qualifies as Most Efficient?

Within 3001/3A01/3B01 Double Hung, 24.9% (36,280 of 145,543) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

What 2026 federal tax credit and Lead RRP rules apply to 3001/3A01/3B01 Double Hung?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 3001/3A01/3B01 Double Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC ASO and product line ASO-A-89 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code ASO and product line ASO-A-89, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Associated Materials, Inc. 3001/3A01/3B01 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros