Window · Vinyl Frame NFRC SBP · Product Line SBP-A-41 ENERGY STAR Most Efficient Eligible

Simonton Building Products, Inc. - Simonton Windows — 07-09 / 07-10 / 07-20 / 07-75 SL · Double Slider

EPA ENERGY STAR Version 7.0 certifies 73,234 variants inside Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 SL, combining Vinyl frame construction with U-Factors spanning 0.18 to 0.32 and SHGC 0.07 to 0.46. Qualifying for Northern, North-Central, South-Central, Southern, this Double Slider family places #477 of 1,352 among 1,352 Window families and posts 0.01 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.18
SHGC Range
0.07-0.46
Certified Options
73,234
Category Standing
#477 of 1,352

How does Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 SL compare thermally against Window peers?

Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 SL achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 07-09 / 07-10 / 07-20 / 07-75 SLHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 07-09 / 07-10 / 07-20 / 07-75 SL (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

07-09 / 07-10 / 07-20 / 07-75 SL Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 SL at rank #477 of 1,352 (tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.07-0.46 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 1,232 configurations meet ENERGY STAR Most Efficient criteria while 3,387 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 108.0 BTU/hr (-18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-08-23 and cert timestamp 2025-03-06.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 73,234 certified glazing combinations for 07-09 / 07-10 / 07-20 / 07-75 SL (NFRC SBP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 3,387 packages (114 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 15,701 packages (522 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 40,533 packages (450 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 68,125 packages (1,157 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Simonton Building Products, Inc. - Simonton Windows produce?

Compare other active Simonton Building Products, Inc. - Simonton Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 SL appear below.

What U-Factor and SHGC range does Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 SL achieve?

Built with Vinyl framing in Dual-Slide Horizontal (HSXX) style, Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 SL offers 73,234 Version 7.0 configurations from U 0.18 up to 0.32, posting -0.02 against the Window median of 0.20 with 1,232 Most Efficient picks.

Which glazing options in Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 SL meet Northern climate limits?

Yes. 3,387 packages in Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 SL clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

What BTU/hr heat transfer results from 07-09 / 07-10 / 07-20 / 07-75 SL's 0.18 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.18 U-Factor yields 108.0 BTU/hr conductive transfer (-18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make 07-09 / 07-10 / 07-20 / 07-75 SL the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 07-09 / 07-10 / 07-20 / 07-75 SL options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 SL in Southern or South-Central zones?

Exactly 68,125 07-09 / 07-10 / 07-20 / 07-75 SL options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.07 rather than higher 0.46 glass.

Does 07-09 / 07-10 / 07-20 / 07-75 SL carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 1,232 of 73,234 07-09 / 07-10 / 07-20 / 07-75 SL glazing builds earn Most Efficient recognition (1.7%), while other variants sit on the standard Version 7.0 tier.

Can homeowners claim Form 5695 credits on Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 SL in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 07-09 / 07-10 / 07-20 / 07-75 SL installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify 07-09 / 07-10 / 07-20 / 07-75 SL after sticker removal?

Verify NFRC ID SBP and series SBP-A-41 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Simonton Building Products, Inc. - Simonton Windows 07-09 / 07-10 / 07-20 / 07-75 SL come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)